Appendix D - ADM Event and Error Codes Overview
313875J
71
A8A6
No Red
Blanket
Current
No current to the conditioning
zone
Alarm
Tripped circuit breaker
Visually check circuit breaker for a tripped condition
A8B5
No Blue
Blanket
Current
Alarm
A8A3
No Red Inline
Current
Alarm
A8B1
No Blue Inline
Current
Alarm
A8A2
No Red Hose
Current
Alarm
A8B4
No Blue Hose
Current
Alarm
Low power
Measure voltage across input terminals on power line
filter. Voltage should measure between 190 and 264
Vac
A8B7
No Red
Chiller
Current
Alarm
Cable unplugged/loose
power
Check for loose or disconnected wires or plugs
A8B8
No Blue
Chiller
Current
Alarm
Bad heater(s)
Measure resistance of heater(s)
A9C1
Motor Over
Current
A software error has occurred
commanding too much current
Alarm
Bad Motor Control
Module code
Check for MCM software update, load latest MCM
software, if problem persists contact Graco
B9C0
Small Shot
Request
The requested dispense
amount is below the minimum
amount of the system (25% of
the combined pump volumes is
the minimum)
Deviation
Pumps are defined with
the wrong size
On the ADM go into the Setup screens to the System
screens then make sure that the pump sizes are
defined correctly
Requested shot is below
the capabilities of the
current pump setup
If the user has to be able to take the shot the system
must be fitted with smaller pumps
CAC1
Comm. Error
Motor
Communication error
Alarm
Loose/broken connection Check connection
CAC3
Comm. Error
Red Tank
Alarm
CAC4
Comm. Error
Blue Tank
Alarm
CAC5
Comm. Error
Mix Head
Alarm
CAC6
Comm. Error
Mix Head 2
Alarm
CAC7
Comm. Error
Ratio Monitor
Alarm
CAA6
Comm. Error
Red Blanket
Alarm
CAB5
Comm. Error
Blue Blanket
Alarm
CAA3
Comm. Error
Red Inline
Alarm
CAB1
Comm. Error
Blue Inline
Alarm
CAA2
Comm. Error
Red Hose
Alarm
CAB4
Comm. Error
Blue Hose
Alarm
Module not programmed Program the module
CAA7
Comm. Error
Red Chiller
Alarm
Module missing power
Check power supply connection
CAB8
Comm. Error
Blue Chiller
Alarm
Module bad
Replace module
D1A1
Setpoint Not
Reached
The set point was not reached
and the pump was shutdown
Deviation
Material restriction too
high for requested flow
Reduce flow request
Error
Code
Error Name
Error Description
Error
Type
Cause
Solution
Содержание VPM 12
Страница 9: ...A Red and B Blue Components 313875J 9...
Страница 11: ...Component Identification 313875J 11 FIG 2 Component Identification ti17702a AJ AF AL AD AC VPM 25 shown...
Страница 12: ...Component Identification 12 313875J VPM 12 FIG 3 ti17703a AL AA AK AH AE AB AD AF AJ AL AD AC AC...
Страница 50: ...Maintenance 50 313875J...