Appendix D - ADM Event and Error Codes Overview
313875J
75
T4B5
Blue Tank
High Fluid
Temp.
Fluid temperature is above the
defined high alarm limit
Alarm
Defective RTD
Replace RTD
T4A3
Red Inline
High Fluid
Temp.
Alarm
T4B1
Blue Inline
High Fluid
Temp.
Alarm
T4A2
Red Hose
High Fluid
Temp.
Alarm
T4B4
Blue Hose
High Fluid
Temp.
Alarm
T4A7
Red Chiller
High Fluid
Temp.
Alarm
Defective High Power
Temperature Control
Module
Replace High Power Temperature Control Module
T4B8
Blue Chiller
High Fluid
Temp.
Alarm
Loose connections
Tighten connections
T4C1
Motor Control
High Temp.
The temperature the MCM has
reached a level where product
life will be decreased
drastically and has been
shutdown for protection
Alarm
No power to fan
Check cord to make sure fan has power
Debris in fan or heatsink Clear debris from fan or heatsink
Low air volume from fan
Try to stop fan by lightly pressing on the center with a
pencil eraser. If the fan slows down easily it will need
to be replaced
Motor may be damaged Replace motor
Debris is packed in the
MCM’s heat sink fins
Clear debris from MCM heat sink fins
T4H1
Oil Temp.
Shutdown
The hydraulic oil is at a
temperature where
performance is impacted
significantly and has resulted
in a system shutdown
Alarm
No Power to Fan
Check cord to make sure fan has power
Debris in fan or fan grill
Clear debris from fan/fan grill
Low air volume from fan
Try to stop fan by lightly pressing on the center with a
pencil eraser. If the fan slows down easily it will need
to be replaced
T4N1
Motor Temp.
Shutdown
Motor temperature is too high
and system has been
shutdown to prevent possible
damage
Alarm
No power to fan
Check cord to make sure fan has power
Debris in fan or fan grill
Clear debris from fan/fan grill
Low air volume from fan
Try to stop fan by lightly pressing on the center with a
pencil eraser. If the fan slows down easily it will need
to be replaced
Ambient environmental
conditions are too hot
Move machine to an area below 120°F
Motor may be damaged Motor may need to be replaced
T6A6
Red Tank
RTD Fault
RTD 1 is giving no or invalid
data
Alarm
Loose or bad connection Check RTD wiring
T6B5
Blue Tank
RTD Fault
Alarm
T6A3
Red Inline
RTD Fault
Alarm
T6B1
Blue Inline
RTD Fault
Alarm
T6A2
Red Hose
FTS Fault
Alarm
T6B4
Blue Hose
FTS Fault
Alarm
T6A7
Red Chiller
RTD Fault
Alarm
T6B8
Blue Chiller
RTD Fault
Alarm
Bad RTD
Replace RTD
Error
Code
Error Name
Error Description
Error
Type
Cause
Solution
Содержание VPM 12
Страница 9: ...A Red and B Blue Components 313875J 9...
Страница 11: ...Component Identification 313875J 11 FIG 2 Component Identification ti17702a AJ AF AL AD AC VPM 25 shown...
Страница 12: ...Component Identification 12 313875J VPM 12 FIG 3 ti17703a AL AA AK AH AE AB AD AF AJ AL AD AC AC...
Страница 50: ...Maintenance 50 313875J...
Страница 86: ...Appendix E USB Operation 86 313875J...