Appendix D - ADM Event and Error Codes Overview
313875J
69
Appendix D - ADM Event and Error Codes Overview
Event Codes
Event Code and
String
Triggers
EAA0-R: Base Purge Base purge performed
EAD0-R: Pump(s)
Parked
One or both pumps were parked
EA10-R: Red Pump
Prime
The red pump has been primed
EA20-R: Blue Pump
Prime
The blue pump has been primed
EA00-R: Disp.
Occurred (Shot #)
A dispense has occurred of the given
shot number.
EAR0-R: Night Mode
Recirc On
While in night mode the system has
automatically entered a low recircula-
tion mode and attempted to turn on all
enabled conditioning zones.
EB00-R: Stop Button
Pressed
The Red stop button was pressed on
the Advanced Display Module.
EBR0-R: Night Mode
Recirc Off
While in night mode the system has
automatically stopped the low recircu-
lation mode and turned off all condi-
tioning zones.
EBR1-R: Setup val-
ues changed
One or more of the setup values has
changed.
ECA1-R: Red Mate-
rial SG Modified
The Red materials specific gravity was
modified.
ECB2-R: Blue Mate-
rial SG Modified
The Blue materials specific gravity was
modified.
ECH0-R: Learn Mode
Executed
A learn mode calibration was success-
fully completed.
EH00-R: Gel Timer
Dispense
The gel timer expired and the system
automatically took the gel shot.
EL00-R: System Pow-
ered On
The System was powered on.
EM00-R: System
Powered Off
The System was powered off.
ENC1-R: Cal. Point 1
Weight Entered
A value for the first point in the three
point calibration was entered.
ENC2-R: Cal. Point 2
Weight Entered
A value for the second point in the
three point calibration was entered.
ENC4-R: Cal. Point 1
Weight Erased
The running average for point one of
the three point calibration was erased.
ENC5-R: Cal. Point 2
Weight Erased
The running average for point two of
the three point calibration was erased.
END0-R: Ratio Check
Dispense
A ratio check shot was dispensed from
the ratio check calibration screen.
ENN0-R: Automatic
Cal. Performed
The system was successfully charac-
terized with the Automatic calibration.
EQU1-R: Settings
Downloaded
The system settings were successfully
transferred from the ADM to a USB
drive.
EQU2-R: Settings
Uploaded
The system settings file was success-
fully transferred from the USB drive to
the ADM.
EQU3-R: Language
Downloaded
The custom language file was suc-
cessfully transferred from the ADM to a
USB drive.
EQU4-R: Language
Uploaded
The custom language file was suc-
cessfully transferred from the USB
drive to the ADM.
EQU5-R: Logs Down-
loaded
The Error/Event and Shot data logs
were successfully transferred from the
ADM to a USB drive.
ER01-R: Shot Count
Reset
A counter from the shot counters main-
tenance page was erased
ER02-R: Seq. Posi-
tion Count Reset
A counter from the sequence counters
maintenance page was erased
ERA1-R: Red Mate-
rial Volume Reset
The resettable totalizer for the Red
material volume was reset to zero.
ERA2-R: Red Mate-
rial Weight Reset
The resettable totalizer for the Red
material weight was reset to zero.
ERA3-R: Red Cycle
Count Reset
The resettable cycle counter for the
Red pump was reset to zero.
ERB1-R: Blue Mate-
rial Volume Reset
The resettable totalizer for the Blue
material volume was reset to zero.
ERB2-R: Blue Mate-
rial Weight Reset
The resettable totalizer for the Blue
material weight was reset to zero.
ERB3-R: Blue Cycle
Count Reset
The resettable cycle counter for the
Blue pump was reset to zero.
Event Code and
String
Triggers
Содержание VPM 12
Страница 9: ...A Red and B Blue Components 313875J 9...
Страница 11: ...Component Identification 313875J 11 FIG 2 Component Identification ti17702a AJ AF AL AD AC VPM 25 shown...
Страница 12: ...Component Identification 12 313875J VPM 12 FIG 3 ti17703a AL AA AK AH AE AB AD AF AJ AL AD AC AC...
Страница 50: ...Maintenance 50 313875J...
Страница 86: ...Appendix E USB Operation 86 313875J...