Technical Data
72
332305B
Technical Data
A
Maximum Working Pressure
5100 psi (35.1 MPa, 351.6 bar)
Power
100-240 VAC
88 - 264 VAC; 0.8 A current, 90 VA Power, 47/63 Hz,
Single phase, inrush/locked rotor, max 40A (1ms)
12 VDC
9 - 16 VDC; 5 A current, 60 W, inrush/locked rotor 12 A
24 VDC
18 - 32 VDC; 2.5 A current, 60 W, inrush/locked rotor 6 A
Outputs - Alarm Relay
Rated Load
Resistive: 0.4 A at 125 VAC, 2 A at 30 VDC
Inductive: 0.2 A at 125 VAC, 1 A at 30 VDC
Max Operation Voltage
Resistive: 250 VAC, 220 VAC
Inductive: 250 VAC, 220 VDC
Max Operating Current
Resistive: 3 A (AC), 3A (DC)
Inductive: 1.5 A (AC), 1.5 A (DC)
Max Switching Capacity
Resistive: 50 VA, 60 W
Inductive: 25 VA, 30 W
Min Permissible Load
Resistive: 10
µ
A, 10m VDC
Inductive: 10
µ
A, 10m VDC
Outputs - Vent Valve
Required Vent Valve Type
Normally closed
Output Voltage
100/240 VAC
24 VDC
12 VDC
Input Voltage
24 VDC
Input Voltage
Max Operating Current
2 A
Max Operating Power
48 W
Inputs - Cycle Pressure, 1, 2, 3, Machine Count
Required Switch Type
Normally open (sink, source, or dry contact)
Sensor Voltage
100/240 VAC
24 VDC
12 VDC
Input Voltage
24 VDC
Input Voltage
Load Current
100/240 VAC
22mA @ 24 VDC
12 VDC
11mA @ 12 VDC
24 VDC
22mA @ 24 VDC
Maximum Residual Voltage
100/240 VAC
4 V
12 VDC
2 V
24 VDC
4 V
Maximum Off Current
100/240 VAC
1.5 mA
12 VDC
1 mA
24 VDC
1.5 mA
Input Impedance
1.1 K
Response Time
60 ms
Cycle Rate
8.0 Hz (50% duty cycle)