Run Mode
332305B
51
Run Mode
Time Control
After setup is complete, the G3 automatically begins to
run the OFF Time sequence (F
IG
. 28).
•
The G3 runs the programmed OFF sequence.
(Notice the OFF Time LED on the display lights and
the OFF Time counts down on the display.)
•
The example shown in F
IG
. 28 shows an OFF Time
of 1 hour and 32 minutes before the lubrication
cycle begins.
•
When the OFF Time count reaches zero, the G3
Automatic Lubrication Pump turns the pump on and
it runs for the programmed ON Time cycle (F
IG
. 29).
(Notice the ON Time LED is now illuminated on the
display.)
•
The example shown in F
IG
. 29 shows an ON Time
of 8 minutes and 42 seconds before the lubrication
cycle ends.
•
When the ON Time count reaches zero, the pump
shuts off again and the system again runs OFF
Time cycle and the OFF Time LED is now again illu-
minated (F
IG
. 28).
This sequence repeats itself until the device is
reprogrammed or an alarm occurs.
•
If power to the pump is lost during a lubrication
cycle, when power is restored the pump will resume
the cycle with the same amount of time remaining in
the cycle as when the power was lost.