Troubleshooting
332305B
63
In an Injector System without sensor
feedback, unit does not vent properly
Vent valve time needs to be config-
ured
Refer to Advanced Programming to
set ON Time, page 45.
Display acts erratically
Faulty cycle/pressure wiring connec-
tion to unit
Unplug cycle/pressure cables from
G3. Plug cables in one at a time to
identify the faulty connection.
USB Error 00
Flash drive was removed during
operation
Keep the flash drive plugged in until
the unit has completed the operation.
USB Error 07
Flash drive unable to mount (initial-
ize)
•
Unplug the flash drive and
re-install.
•
Cycle power and re-install the
flash drive.
•
Retry using a different flash
drive.
If any of the above do not rectify the
error, contact Graco Customer Ser-
vice.
USB Error 11
Pump program setting file not found
Verify that the pump program setting
folder structure and file are stored
correctly on the flash drive. See Stor-
ing Pump Program Settings to the
Flash Drive, page 37 for instructions.
USB Error 12
Pump program settings directory not
found.
Verify that the pump program setting
folder structure and file are stored
correctly on the flash drive. See Stor-
ing Pump Program Settings to the
Flash Drive, page 37 for instructions.
USB Error 13
Bad pump program settings file
The pump programs settings file is
corrupt. Restore file to the flash drive.
See Storing Pump Program Settings
to the Flash Drive, page 37 for
instructions.
All other USB errors
The following operations can be
attempted if another error occurs
using the USB.
•
Unplug the flash drive and rein-
stall.
•
Cycle power and re-install the
flash drive.
•
Retry using a different flash
drive.
If any of the above do not rectify the
error, contact Graco Customer Ser-
vice.
Problem
Cause
Solution