Alarms
58
332305B
Low Level
Fault
Level of lubricant in
reservoir is low and addi-
tional lubricant needs to be
added.
Unit stops pumping and
displays amount of accu-
mulated time since the
alarm was triggered.
Add lubricant to reservoir.
After lubri-
cant is
added press
and hold the
RESET button to clear
fault.
If repriming pump is
required, the low level
alarm time should be
decreased. See A-2:
Advanced Programming,
Low Level Alarm Time
page 47.
Cycle /
Pressure
Warning
System fails to relieve
pressure or a lubrication
cycle was not completed in
the user-defined amount of
time.
Unit will continue to oper-
ate for the number of lubri-
cation cycles set by the
warning retry parameter
(see Advanced Program-
ming, page 45).
If the warning condition
clears itself on the next
automatic lubrication cycle,
the warning is cleared and
the unit continues normal
operation.
Examine system to deter-
mine if you have a
plugged or broken line or
other component failure,
i.e., divider valve, injector.
Press the
RESET but-
ton to clear
warning.