Remote DataTrak Operation
334222B
13
NOTE:
If you go past a field you want to edit, toggle
through the remaining fields, exit the Setup mode, and
reenter Setup. It is impossible to back up in the Setup
screens.
2. Press
to scroll through available values for each
field.
3. Press
again to set the value and move the cur-
sor to the next data field.
Runaway Cycle Rate/Enable Runaway
Protection
NOTE:
Graco recommends setting run-
away cycle rate (RS) to 60 or less. Choose
a value that is just above the maximum
cycle rate of the application.
NOTE:
When runaway protection is enabled (RT), a
will appear on the setup screen. See F
Displacement Pump Volume
Press
to scroll through the available displace-
ment pump volumes (PV) in cc per cycle. set the
values to the pump size installed.
Flow Rate Units
Press
to scroll through the available flow rate
units. See
Key
on page 10. The selected units will
be used to display flow rate and volume on the main
Run screen and most of the setup values.
NOTE:
Initially, choose units that will allow easy defini-
tion of the setup values (e.g. drum volume in gallons).
Then, return and select the flow rate unit to display on
the Run screen. The defined setup values will convert
automatically.
Drum Size
Use DS to enter the size of the container.
Drum Fill Volume
Use the Drum Fill Volume field (DF) to enter the
exact volume of material in the drum. Contact sup-
plier for exact volume. This value is used to deter-
mine the remaining volume in the drum.
4. To move to Setup screen 2, move the cursor to the
Drum Fill Volume field (DF), then press
once
more.
Setup Screen 2
Use Setup screen 2 to set the maintenance counter set-
point (MC), reset the maintenance counter, enable/dis-
able diagnostic codes (EC), and choose whether the E7
drum icon (DL) will indicate when the drum is low or
when the drum is completely empty.
1. Press
to toggle from field to field through the
screen.
2. Press
to scroll through available values for each
field.
3. Press
again to set the value and move the cur-
sor to the next data field.
Maintenance Counter
Use the maintenance counter setpoint (MS) to set
the maintenance schedule based on the units dis-
played. Press and hold
for 3 seconds when the
entire MS field is highlighted to reset the MC value.