57
Metering Pump Inlet Filter
Operation
The pump inlet filter is to prevent particulate matter from damaging the
precision metering pumps. The filter element is a bag type and should it
become clogged, it will cause cavitation of the pump resulting in damage
to the pump.
Therefore, it is necessary that the filter be properly
serviced at all times.
The Pre Polymer element is a 400 micron nylon bag and the Curative
element is a 150 micron nylon bag.
If the pressure at the inlet of the metering pump falls below the factory
setting of 40 psi, an alert warning will occur and both pumps will
shutdown. This is an indication that:
•
The filter may need to be serviced.
•
The buffer tank pressure is too low.
•
The buffer tank is not up to temperature.
Maintenance
During the first week of operation, the filter should be opened and the bag
inspected. If the element is dirty, replace it. After the condition of the raw
material has been determined, the cleaning interval can be adjusted.
Service in accordance with the procedures in the Maintenance Manual.
Note:
Do not attempt to clean the filter element, always replace it with a new
one.
Never check the filter prior to an extended shutdown as this may introduce
moist air into the system that will remain during the shutdown period and
may react with the chemical.
Caution:
HAND
TIGHTEN ONLY
Содержание BetaCell 241D
Страница 6: ...6...
Страница 8: ...Specifications System Dimensions 54 108 98 3 16...
Страница 11: ...11 DESCRIPTION OF CONTROLS 1...
Страница 15: ...15 Help Screen A Help Screen is available for each of the Menu Screens...
Страница 24: ...24 Maintenance Menu Press to access the Maintenance screen Password Required...
Страница 30: ...30 AutoStart Set Up Screen This screen is for qualified technicians only...
Страница 31: ...31 Sleep Mode Set Up Screen This screen is for qualified technicians only...
Страница 37: ...37 DESCRIPTION OF MAJOR COMPONENTS 2...
Страница 38: ...38 System Schematic...
Страница 44: ...44 Buffer tank 2 1 6 7 5 8 9 4 3...
Страница 45: ...45 13 10 12 Fumes piped away by others in accordance with plant specifications 11...
Страница 55: ...55 AutoFill Valve Maintenance There is no normal operating maintenance Position Indicator...
Страница 65: ...65 Hydraulic Power Pack Schematic...
Страница 78: ...78 DAILY PROCEDURES 4...
Страница 80: ...80 FAULT MANAGEMENT 5...
Страница 88: ...88 MAINTENANCE 6...