104
Gusmer Part
No.
Description Procedure Time
54250-5
54250-6
3’ Hydraulic
Hose
254.Turn hydraulic power unit off via HMI
255.Relieve pressure by turning needle valve below
Accumulator, CCW and verify pressure is 0 psi
256.Remove hydraulic hoses from dispensing gun and
replace with new
257.Before attaching to gun, attach ends of hoses together
with a 7/16 JIC union
258.Close needle valve
259.Turn hydraulic power unit on via HMI for several
minutes to remove air in lines
260.Turn hydraulic power unit off via HMI
261.Relieve pressure by turning needle valve below
Accumulator, CCW and verify pressure is 0 psi
262.Remove union and attach hose ends to dispensing gun
(black/pressure attaches to 90º fitting on back of gun;
black-white/return attaches to extended gun fitting)
263.Turn hydraulic power unit on via HMI; verify gun is
closed at tip
264.Verify leak free
Tools: Open End Wrenches
15 min
54250-1
54250-3
3’ A-Supply
Hose
3’ A-Return
Hose
265.Turn Prepoly pumps off.
266.Bleed air from Buffer tank
267.Lock out ball valve on bottom of buffer tank
268.Lock out inlet air ball valve
269.Close Pre Poly valves on Coupling block
270.Remove and replace hose
271.Open valve on coupling block
272.Open locked out valves
273.Apply air to system
274.Start chemical pump and recirculate chemical
275.Verify leak free
Tools: Open End Wrenches
15 min
Содержание BetaCell 241D
Страница 6: ...6...
Страница 8: ...Specifications System Dimensions 54 108 98 3 16...
Страница 11: ...11 DESCRIPTION OF CONTROLS 1...
Страница 15: ...15 Help Screen A Help Screen is available for each of the Menu Screens...
Страница 24: ...24 Maintenance Menu Press to access the Maintenance screen Password Required...
Страница 30: ...30 AutoStart Set Up Screen This screen is for qualified technicians only...
Страница 31: ...31 Sleep Mode Set Up Screen This screen is for qualified technicians only...
Страница 37: ...37 DESCRIPTION OF MAJOR COMPONENTS 2...
Страница 38: ...38 System Schematic...
Страница 44: ...44 Buffer tank 2 1 6 7 5 8 9 4 3...
Страница 45: ...45 13 10 12 Fumes piped away by others in accordance with plant specifications 11...
Страница 55: ...55 AutoFill Valve Maintenance There is no normal operating maintenance Position Indicator...
Страница 65: ...65 Hydraulic Power Pack Schematic...
Страница 78: ...78 DAILY PROCEDURES 4...
Страница 80: ...80 FAULT MANAGEMENT 5...
Страница 88: ...88 MAINTENANCE 6...