background image

Graco Ohio Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in 
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty 
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by 
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written 
recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty 
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of 
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with 
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or 
maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of 
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned 
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will 
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED 
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy 
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or 
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT 
MANUFACTURED BY GRACO

. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to 

the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these 
warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or 
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the 
negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, 
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la 
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite 
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Ohio Information

For the latest information about Graco products, visit www.graco.com

TO PLACE AN ORDER, 

contact your Graco distributor or call to identify the nearest distributor.

Toll Free: 

1-800-746-1334

 or Fax: 

330-966-3006

All written and visual data contained in this document reflects the latest product information available at the time of publication. 

Graco reserves the right to make changes at any time without notice.

This manual contains English. MM 313813

Graco Headquarters: 

Minneapolis

International Offices: 

Belgium, China, Japan, Korea

GRACO OHIO INC. 8400 PORT JACKSON AVE NW, NORTH CANTON, OH 44720

Copyright 2009, Graco Ohio Inc. is registered to ISO 9001

www.graco.com

Содержание Aerobotix RC50

Страница 1: ...8023 3000 psi 21 MPa 206 bar Maximum Fluid Working Pressure 80 psi 550 kPa 5 5 bar Maximum Air Inlet Pressure Important Safety Instructions Read all warnings and instructions in this manual and all su...

Страница 2: ...e Circulation 42 Pouring Requirements 42 Beginning the Pour 42 Night Mode Operation 43 Starting Night Mode 43 Requirements for Continuing Night Mode 43 Shutdown 44 Overnight Weekend 44 Long Term Shutd...

Страница 3: ...ngs Filters Flow Meter Cable Heat Exchanger Level Sensors Motors Pump and Motor Assembly Sub Component Manuals Manual No Relates to Part Description U80756 All Assembly Drawings Manual 309475 234269 H...

Страница 4: ...ash can shock burn or cause death An arc flash in explosive atmospheres can cause an explosion Do not install the Main Control Panel which is not intrinsically safe in a hazardous area as defined in A...

Страница 5: ...SA or your local electrical code Do not install the Main Control Panel which is not intrinsically safe in a hazardous area as defined in Article 500 of the National Electrical Code USA or your local e...

Страница 6: ...ildren and animals away from work area Comply with all applicable safety regulations TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on s...

Страница 7: ...pressure especially if agitated To reduce frothing minimize preheating in a circulation system Changing Materials When changing materials flush the equipment mul tiple times to ensure it is thoroughly...

Страница 8: ...56 for further Graco component identification See non Graco component manuals for further non Graco component identification FIG 1 RC50 Base Front View Key AA Heat Exchangers AB Pressure Gauges AC Vol...

Страница 9: ...ponent Identification 313813A 9 FIG 2 RC50 Base Rear View Key AJ Poly Tank Agitator AK Poly Tank AL Iso Tank AM Iso Filter AN Iso Heater AP Iso Tank Agitator AK AL ti14338a AN POLY Side ISO Side AJ AP...

Страница 10: ...n Light DC Control Power On Button DD Emergency Stop Button DE Main Disconnect Switch DF Warning Labels DG Main Control Panel DE DA DB Replacement Danger and Warning labels tags and cards are availabl...

Страница 11: ...mponents is allowed only if high integrity equipotential system is realized between the points of bonding Do not operate system with safety barrier cover removed Main Control Panel Install in the non...

Страница 12: ...rol panel This wiring must not come near or in contact with any non intrinsically safe wiring 2 Any replacement of intrinsically safe barriers must be an identical replacement to maintain intrinsicall...

Страница 13: ...Disconnect Switch DE 2 Ground the Main Control Panel to a true earth ground See Grounding page 14 Connect Main Control Panel to Main Junction Box See U80638 schematic Connect Main Control Panel to Pum...

Страница 14: ...ue earth ground through main control panel See U80638 schematic Pumpline Motors Connect a ground wire to a true earth ground through main control panel See U80638 schematic Agitator Motors Connect a g...

Страница 15: ...C50 Base Module Applicator Group not all items shown NOTE Assemblies not shown to scale NON HAZARDOUS LOCATION ONLY HAZARDOUS CLASSIFIED LOCATION CLASS I DIV I GROUP D Poly Tempered Water Unit Iso Tem...

Страница 16: ...alarm inactive Iso and Poly High Pressure alarms inactive Iso and Poly Tank Low Level alarms inactive See Alarms List page 59 for more information Starting Metering Pump Motors Navigate to the Machin...

Страница 17: ...Tank Control screen access BK Pour Time Editor screen access BL Setup screen access BM Flow Control screen access BN Scaling screen access BP Alarm HIstory screen access BR Alarm Status screen access...

Страница 18: ...gain access to the Scaling screen the user must log in as a Maintenance user Password 10 The Factory user name is reserved for Graco factory personnel to set initial parameters on the machine Setting...

Страница 19: ...on the Iso side FIG 7 4 5 1 6 2 1 Status is indicated by a red background and the word OFF or a green background and the word ON The path the fluid follows is indicated by these lines When the line i...

Страница 20: ...ll status MixHead Status Indicators The Status Screen includes several indicators that show machine operation status MixHead Pour Ready Indicator shows green when all requirements are made for beginni...

Страница 21: ...the HMI The material will dispense for the duration of time assigned to the channel set The time duration can be set for each chan nel under the Pour Time Editor Automatic Mode Status The Automatic Mo...

Страница 22: ...w Information Motors Start and Stop Buttons These buttons control whether a specific motor is run ning and the current status of each motor will be dis played below each set of buttons System Outlet C...

Страница 23: ...Key EA Auto Fill On Off EF Fail to Fill Alarm Delay EG Fill Delay Iso Poly Temperature Control The Temperature Control Screen is accessible by press ing the Temperature Control button See Temperature...

Страница 24: ...tor is on and the asso ciated temperature control is on the indicator below will indicate ON and when it is off it will indicate OFF When temperature control is on but the associated metering pump mot...

Страница 25: ...en allows entry of a pour time preset for each of the 99 available channels To access different groups of presets push the First Group Prev Group Next Group and Last Group buttons To change a particul...

Страница 26: ...ravity GD Cleanout Delay setting GE Cleanout Extend Time setting GF Pressure Hold Time See Settings section on page 45 for more information Night Mode On Off Time See Night Mode Operation on page 43 f...

Страница 27: ...Setpoint HL Automatic Mode Ratio Setpoint Iso divided by Poly HM Automatic Mode Total Flow Setpoint grams per second HN Iso Hi Speed Calibration Setpoint Percent HP Iso Low Speed Calibration Setpoint...

Страница 28: ...control When outside the warning range an alarm will be displayed When outside the shutdown range the MixHead will not shoot High Low Speed Calibration Percent This is the high and low calibration spe...

Страница 29: ...ding grams per second JL Test Flowrate grams per second See Calibrating Machine Calculated Mass Flow on page 50 for more information Flowrate Filter The flowrate input and display may be filtered to p...

Страница 30: ...n Key KA Up Scale KB Down Scale KC Pen KD Move Left KE Home KF End KG Pause KH Move Right This screen is accessible from the Scaling screen FIG 16 This screen is for qualified technicians only and is...

Страница 31: ...Operation 313813A 31 Alarm History and Alarm Status Screens See Troubleshooting section on page 57 for Alarm screens details...

Страница 32: ...or MD Level Sensor ME Metering Pump Inlet Filter MF Tank Outlet to Pump Ball Valve MG Water Separator MH Tank Fluid Level Sight Gauge MJ Tank Outlet Ball Valve MK Day Tank Incoming Air Valve ML Tank D...

Страница 33: ...properties Turn clock wise to increase sensitivity and counterclockwise to decrease sensitivity Metering Pump Inlet Filter Air Pressure System The air supplied to the machine must be dry To remove exc...

Страница 34: ...ing Pump Low Inlet Pressure switch will cause a warning alert and the affected metering pump motor will shutdown See the table at the beginning of the Set tings section on page 45 for switch setting...

Страница 35: ...o maintain the desired fluid temper atures Tempered Water Unit The stand alone tempered water units improve the effi ciency of the heat exchanger The function of the tem pered water units are to cool...

Страница 36: ...old Circulation Valve A pneumatically operated Circulation Valve remotely mounted allows low pressure operation at startup and between shots It transfers flow from the outlet of the flow meter through...

Страница 37: ...cy drive enables control of the metering pump motor rpm as well as advanced flow control from the HMI See Adjusting Metering Pump Motor RPM on page 48 and Calibrating Machine Calculated Mass Flow on p...

Страница 38: ...in an area that permits easy access to all areas of the machine for maintenance and operation The metering unit was plumbed wired and tested at the factory For transporting purposes the unit was drain...

Страница 39: ...Setup 313813A 39 Dispense Gun Hoses Key SA Poly Return to Tank SB Poly Pressure SC Iso Pressure SD Iso Return to Tank FIG 21 Dispense Gun Hose Setup SB SA SC SD ti14338a1...

Страница 40: ...a tion mode and readies itself for dispensing 6 The RC System turns on the RC System Ready for Dispense signal 7 The Robot System turns on the Robot System Dis pense command 8 The RC System opens the...

Страница 41: ...p Inlet Filter During the first week of operating a new machine the fil ter should be inspected every other day If the element is dirty clean it with solvent or replace it with a new one as required S...

Страница 42: ...utton has been pressed but Pres sure Build Time has not yet elapsed A pour has finished but High Pressure Hold Time has not yet elapsed Pouring Requirements The following requirements must be met in o...

Страница 43: ...urned off and off time begins This sequence of going from off time to on time and back will continue until Night Mode is turned off To see how the night mode information is displayed see Status Screen...

Страница 44: ...tch spilled material remove lowest hose from heat exchanger This will empty the heat exchanger and heater and all chemical lines above 7 Tighten metering pump drain plug and reattach heat exchanger ho...

Страница 45: ...heater works to heat the material by exposing the chemical to heated rods that are turned on and off as necessary Temperature Setpoint The temperature setpoint is the goal temperature for the chemica...

Страница 46: ...to faster heating at initial startup but will increase the temperature fluctuation Lower gains will lead to smaller temperature mar gins and slower heating at initial startup Lower chemical flow rates...

Страница 47: ...e Setup screen see FIG 13 on page 26 This is the time that the meter ing system will stay in high pressure after a pour has been completed This time should be increased if shots are to be performed in...

Страница 48: ...t Mode must be off Appropriate Metering Pump Motors must be on When the preceding requirements are met 1 Select manual mode and high pressure override to put the machine into high pressure circulation...

Страница 49: ...ed 1 With one person standing at the HMI and the other at the metering pump turn dial put the machine in calibrate mode 2 Navigate to the Status screen to view the flowrate 3 Turn the metering pump di...

Страница 50: ...Factor inputs for each chemical The flow meters are calibrated at the factory and will never need to be calibrated unless harmful materials pass through them such as solvents or materials includ ing...

Страница 51: ...r as Necessary 16 Remove the calibration bucket weigh and calculate the dispensed material weight 17 On the scaling screen the weight of the shot calcu lated by the machine will be shown If this match...

Страница 52: ...e to the off position and lockout 23 Relieve air pressure hydraulic fluid pressure and chemical line pressure See Pressure Relief Pro cedure on page 53 24 Open valve on blocked chemical side Repeat fo...

Страница 53: ...he tanks Chemical Line Pressure Relief 1 Turn off and lockout main power 2 Relieve tank air pressure See Air Pressure Relief procedure 3 Ensure there is no pressure in the chemical lines by looking at...

Страница 54: ...nd o ring as required 6 Liberally coat the o ring and surrounding surfaces with a moisture free grease Procedure Frequency Purge Air from Metering Pump Daily before use Drain the Water Separator Daily...

Страница 55: ...mps and fittings as necessary Check Hoses for Wear Look for wear on all hoses where they come into contact with anything Over time rubbing may wear down the hose and increase the chance for a hose rup...

Страница 56: ...ng of material from the 5 psi charge 7 Close the tank supply valve and replace the drain plug If no further maintenance is anticipated leave the 5 psi charge of dry air on the tank Otherwise vent the...

Страница 57: ...rm conditions are indicated on the Alarm Status screen which can be selected from the menu bar along the bot tom of all screens A new alarm condition will cause an alarm to sound and the new alarm mes...

Страница 58: ...ory Screen This screen stores all alarms that have been triggered See the table at the beginning of the Settings section on page 45 for pressure and temperature switch settings FIG 23 Sort button Push...

Страница 59: ...ecified on the Flow Control Screen this alarm will be displayed Iso Poly Metering System Alarms Iso Poly Pump Motor Overload Alarm This alarm causes an immediate stop of the meter ing pump motor If th...

Страница 60: ...30 minutes after startup to allow for chemical temperatures to stabilize Iso Poly MAG Drive High Temperature This alarm exists only for machines with MAG drives The alarm is triggered when the MAG dri...

Страница 61: ...ctor on pressure switch Iso Poly Pump Low Pour Pressure or Failure to Build Pressure Alarm banner Red fault light ON Fault horn ON MixHead locked CLOSED 1 Check air supply pressure 2 Adjust Iso Poly j...

Страница 62: ...6312 18 3 Oiler 1 1 17746 13 Gauge 0 160 PSI 2 1 Tank Agitators Part List for one Agitator Assembly U70375 Agitator Assembly Exp Proof 1 1 0128 3 Agitator Cover Gasket 1 1 20021 3 28 Gasket 150 Flange...

Страница 63: ...1 6690 24 155 Fuse 100A LPJ 100SP 3 3 6690 24 160 Fuse Adapter 3 3 6690 24 164 Fuse Fuse block 26 5 6690 24 37 Fuse 30A LPJ 30SP 6 3 6690 24 35 Fuse 20A LPJ 20SP 6 3 6690 24 293 Fuse Class J 15A Time...

Страница 64: ...Contact Block NC Self Monitoring 1 1 6690 1 42 Relay Base 8 4 6690 1 40 Relay DPDT 8 4 6690 1 41 Relay Ret Clip 8 4 V Z787 Meter Flowmeter 24VDC Intrins 2 1 U70202 Barrier Instrinsically Safe 4 2 U70...

Страница 65: ...mperature 180 F 82 2 C Output 8 75 50 lb min at a 2 5 1 ratio Iso rich Day tank capacity each Poly 20 gallons 75 7 liters nominal Iso 60 gallons 227 1 liters nominal Sound power per ISO 9614 2 76 5 dB...

Страница 66: ...other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available...

Отзывы: