GPS1195 Auto Gate Manual                                                                              Version 3 

Installation Set Up 

Installation of all equipment should be performed by trained personnel, skilled in the type of work 
involved. All installations should be inspected by appropriate authorities, or a factory trained 
representative, before the system is put into operation.  

Note: 

    

Do not remove the plastic bag from the piece of equipment until the unit is placed in the 

correct location according to the information tag attached to the top of the plastic bag. Refer to your 
layout drawings for correct equipment placement 

1)

 

Remove packaging carefully so as not to damage the paint finish 

2)

 

Unlock & Remove the door 

3)

 

Carefully place the gate in the correct position and mark 4 mounting holes on the concrete 

4)

 

Carefully remove the gate and drill holes suitable for 3/8” x 4” lag bolts.  

5)

 

Place the gate back in position and install bolts and flat washers, lubricate bolts with grease 
when installing 

6)

 

Attach wiring to correct terminals according to field connection drawings supplied. Wiring 
and connector terminals and techniques used must be done according to standard electrical 
codes or statues. Particular attention must be paid to proper grounding. Low voltage circuits 
are class 1 and should be installed accordingly.  

7)

 

Connect each gate to a dedicated 15 AMP, 120Vac circuit breaker. Ensure the complete 
electrical installation is done according to all local Codes / Regulations. 

8)

 

The Gate shall be Powered and Protected through an Approved Ground Fault Circuit 
Interrupter ( GFCI ) at the time of Installation 

9)

 

Door lock keys are attached to the outside of the flange 

10)

 

Limit cam adjustment may be necessary to level the barrier arm in the field. Loosen the wing 
nut that keeps the cam in place and move the cam forward or backwards slightly to level the 
arm properly. Fully re-tighten the cams with the wing nuts when finished.  

11)

 

For the vertical up position of the barrier arm, 

do not adjust with the UP limit cam

. Loosen 

the 2 nuts found on the connecting rod which has one left hand and one right hand eye bolt 
at the top and the bottom of the rod. At the center of the Rod is a flat point. Use a ½” open 
end wrench to turn the connecting rod either left or right until the vertical position of the 
arm is correct. Fully tighten the 2 nuts, each one against an eye bolt. 

12)

 

For barrier arms longer than 14ft, the internal counter balance spring may require a slight 
adjustment in order to balance the arm for a smooth open, close operation of the arm. This 
only applies to newly installed gates 

13)

 

The gear reducer has a pin in the breather plug that is there for transport only so that oil 

does not leak out. This pin must be removed when the gate is to go into operation. 

Page 4A 

Содержание GPS1195

Страница 1: ...LOBAL PARKING SYSTEMS INC TEL 905 405 9800 FAX 905 405 9801 GPS1195 Automatic Barrier Gate INSTALLATION AND MAINTENANCE MANUAL E MAIL Info gpsgates com WEB SITE www gpsgates com DOCUMENT VERSION 4 201...

Страница 2: ...id if any modifications changes or additions to the equipment are performed without written approval from Global Parking Systems In addition this warranty may be voided or further limited if the requi...

Страница 3: ...e 5 Loop Detector Page 6 Loop Installation Page 7A 7B 7C PLC Version 2 Wiring Connections Page 8A 8B 8C 8D 8E Operating Instructions Page 9 Maintenance Page 10 Spring Adjustment Page 11 Power Failure...

Страница 4: ...Connect each gate to a dedicated 15 AMP 120Vac circuit breaker Ensure the complete electrical installation is done according to all local Codes Regulations 8 The Gate shall be Powered and Protected t...

Страница 5: ...and connect the 3 bolts supplied through the arm into the spacer and then the main shaft Never mount the spacer on the outside of the arm as you will damage the paint finish and the arm will become l...

Страница 6: ...ay to provide smooth operation in both directions resulting in lower wear as well as reduced heat and power consumption Maximum run timers for both directions to prevent continuous cycling of barrier...

Страница 7: ...plus all other forms of traffic like motorcycles RV s High bed trucks Trailers Construction vehicles etc The standard detector found in all GPS Equipment is the LMA 1250HV from EDI Failsafe 120vac 22...

Страница 8: ...ield of the cable should be connected to earth ground at the detector only If splices are necessary connect as in 4 above and waterproof 6 All steel beams Iron drains Water pipes etc should be at leas...

Страница 9: ...r Teflon are recommended No splices are to be made in the wire slots 5 Ensure the wires are not loose in the slot as this will cause future loop failure Do not use sharp tools or objects to push wires...

Страница 10: ...e following formula can be used to calculate the approximate inductance of a loop N Number of Turns L N2 X 5 X 1 P Loop perimeter in feet 10 N L Loop inductance in microheneries Loop Area Square Feet...

Страница 11: ...Green or Red Terminal 6 Traffic Light Red or Green Terminal 7 120Vac Line in Black Wire Terminal 8 120Vac Line in Black Wire Terminal 9 120Vac Neutral in White Wire Terminal 10 120V Neutral in White W...

Страница 12: ...Terminal 15 Safety Edge Input Terminal 16 24V Input common Connector 3 Relay Contact Outputs Terminal 1 Lockout contact 1 Common Terminal 2 Lockout contact 1 Normally Closed Terminal 3 Lockout contact...

Страница 13: ...rminal 3 Relay 3 Coil Terminal 4 Relay 4 sign relay Coil Terminal 5 Stop input Terminal 6 Relay 1 Contact 1 Normally Open Terminal 7 Relay 2 Contact 1 Normally Open Terminal 8 Relay 3 Contact 1 Normal...

Страница 14: ...l 7 Relay 3 contact 2 Common Terminal 8 Relay 3 contact 2 Normally Closed Terminal 9 Relay 3 contact 2 Normally Open Terminal 10 Relay 4 contact 3 Common Terminal 11 Relay 4 contact 2 Normally Open Te...

Страница 15: ...minal 11 24Vdc common Terminal 12 24Vdc common Dip Switch Settings Switch 1 On Reset Loop Enabled Switch 1 Off Reset Loop Disabled Switch 2 On Free Loop Enabled Switch 2 Off Free Loop Disabled Switch...

Страница 16: ...Auto Manual switch to raise or lower the gate located to the side of the PLC board nearest the door opening 5 Observe the barrier arm position in up and down positions and adjust limit cams if necess...

Страница 17: ...5W90 Synthetic Gear oil Check and tighten as required all nuts and bolts Check to insure the cabinet is securely mounted to the island Check that all wiring terminals connectors Etc are secure and are...

Страница 18: ...turnbuckle loosen the 24mm nut at the top of the turnbuckle and then loosen the nut at the bottom of the turnbuckle The nut is left hand 4 Loosen the 24mm nut that secures the top of the connecting r...

Страница 19: ...e may start automatically if it is left in the on position and could cause injury 1 Rotate the motor manually using the belt until the up limit cam makes contact with the limit switch 2 Leave the on o...

Страница 20: ...am adjust forward or backwards cycle the gate once up and then down If the position of the gate arm is straight across the lane when closed retighten the down limit cam as much as possible so that no...

Страница 21: ...position of the limit cams located on the main shaft inside the upper part of the gate The up limit switch is marked with a tag UP and the down limit switch is marked with a tag DOWN To adjust the lim...

Страница 22: ...are lit up OOOO O O this way when the gate is down Outputs OOOOOOO O PR E S 0 1 2 3 Up Position When the vehicle moves onto the vend loop Input 0 and Output 1 turn on Inputs 0 1 2 3 4 5 input 3 goes...

Страница 23: ...the up limit switch Auto Manual switch In Auto mode as the arm goes down output 0 lights up Inputs 0 1 2 3 4 5 Input 4 and 5 drop out When the down switch is made output OOOO O O 0 drops out and input...

Страница 24: ...s the open button to raise the barrier input 6 lights once and Inputs 0 1 2 3 4 5 Output 1 lights once Both drop out once up limit switch is made Input 3 turns off as arm is going up O OOOO O Input 4...

Страница 25: ...out and input 4 and 5 stay lit when the up switch is made When you release the latching keyswitch input 4 and 5 drop out Output 0 lights up and when the down switch is made output 0 drops out and inpu...

Страница 26: ...ULLEY GPS 1195 2P 2 X 5 8 MOTOR PULLEY GPS 1195 5P 5 X REDUCER PULLEY GPS 1195 6P 6 X REDUCER PULLEY GPS 1195 FB2 2 HOLE FLANGE BEARING GPS 1195 RS RUBBER SEAL SET FOR MAINSHAFT BEARING GPS 1195 PSW P...

Страница 27: ...D GPS 1195 33VB 4L 330V BELT GPS 1195 34VB 4L 340V BELT GPS 1195 UB 2X4 UTILITY POWER SWITCH BOX GPS 1195 UBC UTILITY BOX COVER GPS 1195 PDS POWER DISCONNECT SWITCH GPS 1195 55SPA 5 5MM SPRING ASSEMBL...

Страница 28: ......

Отзывы: