GPS1195 Auto Gate Manual Version 3
Trouble Shooting
Service should be performed by technicians who are properly trained to repair this equipment
The PLC controller has input and output displays located on the top of the PLC. When the gate is in
working mode the green indicators light up to display which input or output is on.
Vend, Reset application Down Position
When turning the power switch on, Inputs 0 1 2 3 4 5
both inputs and outputs are lit up OOOO O O
this way when the gate is down Outputs OOOOOOO O
PR E S 0 1 2 3
Up Position
When the vehicle moves onto the vend loop Input 0 and Output 1 turn on Inputs 0 1 2 3 4 5
input 3 goes out and Input 4 turns on when up limit is made OOOO O O
Outputs OOOOOOO O
PR E S 0 1 2 3
When the vehicle moves forward and goes over the reset loop
Inputs 0 + 1 and 4 are on including PR outputs
output 0 lights up and output 0 and 4 go out, Input 3 lights up
when down limit switch is made
Arming Loop Application
Inputs 0 1 2 3 4 5
Input 2 + 3 lights up when the vehicle goes over the loop OOOO O O
Outputs OOOOOOO O
PR E S 0 1 2 3