GPS1195 Auto Gate Manual Version 3
Calculating Loop Inductance
The following formula can be used to calculate the approximate inductance of a loop.
N = Number of Turns L = N2 X 5 X 1
P = Loop perimeter in feet 10 + N
L = Loop inductance in microheneries
Loop Area (Square Feet) Number of Turns
6 – 12 6
12-20 5
20-60 4
60-240 3
240 – UP 2
Page 7C