5.11.
I/O Settings
The Logic-5000 supports the following I/Os:
Logic 5000 Input Status: Ignition sense, main voltage, and modem temperature
Four general purpose external analog input lines (AIN1 … AIN4)
Four general purpose external digital input lines (DIN1 … DIN4)
Four general purpose external digital outputs (relay-driven contact closures).
Implemented as four sets of SPST contacts (normally open) (NO1a … NO4b)
See Figure 35 for pin output diagram.
Figure 35 -
Logic-5000 Pin-output. View looking into device.
Digital inputs are internally biased high. To trigger a digital input, connect the pin to
ground.
When digital outputs are triggered, the
a
and
b
pins are connected via an internal relay.
The internal relays are rated for 1A @ 30V, or .3A @ 125VAC.
Pin #
Description
Wiring Harness Color
Pin 1
Analog Input 4 (AIN4)
Not populated*
Pin 2
Analog Input 2 (AIN2)
Not populated*
Pin 3
Analog Ground
Not populated*
Pin 4
Digital Output 4b (NO4b) Red/White
Pin 5
Digital Output 4a (NO4a) Red
Pin 6
Digital Output 2b (NO2b) Purple/White
Pin 7
Digital Output 2a (NO2a) Purple
Pin 8
Not used
Not populated*
Pin 9
Digital Ground
Black
Pin 10
Digital Input 4 (DIN4)
Brown
Pin 11
Digital Input 2 (DIN2)
Orange
Page 53 of 59