76343/4/5 | English, Revision 05 | Date: 23.02.2022
49
Parameter Setting via the Web Interface – Chapter 5
5.3.8 Input (optional)
It is possible to transmit the signal status via the network to other network users or
to switch the onboard relay via the input (s. 5.3.6 on page 47). For the configuration
the following parameters can be used.
5.3.8.1 Input Parameters
Backup NTP Server Here you can define a 2nd NTP server
Timezone
The time server supplies a UTC (Coordinated Universal Time) time. In order to
determine the valid local time, the time zone in which the radio modem is oper
-
ated must be specified here.
Enable DST/
Summertime
In regions with daylight saving time, this option must be activated.
The radio modem can optionally be equipped with a digital input signal on demand
(when ordering). With the input the connectors on the back plane change (s. Figure
3 on page 11). The software allows to configure the input even if the hardware is
not present.
Table 33
Web interface: AUX Input Parameters (part 1 of 2)
Parameter
Function
Enable
Enables the input
Mode
Operating Modes:
Remote Port
Remote IP
IP address and Port of the communication partner to which the
signal state is transmitted via UDP/IP.
TCP-Server Port
TCP-Server IP
IP address and port of the communication partner to which the
signal states are sent via TCP/IP.
Relay Timeout
(nur im Mode
„Relay ON“)
If the internal relay is switched via the input signal, you can set a
time here that the relay should remain switched on. If this time is
set to 0, the time specified in the relay configuration will be used.
ON Text
Character string that is transmitted when the signal is active.
Table 32
Web interface: Realtime Clock (part 2 of 2)
Parameter
Function
Table 34
Web Interface: AUX Input Modes
Mode
Function
UDP
Sends the state via a UDP socket (Remote IP :
Remote Port)
TCP-Client
Sends the state to a TCP Server socket (TCP-
Server-IP : TCP-Server Port)
Relay ON
Switches the relay on when the input is active
Relay OFF
Switches the relay off when the input is active
Relay toggle
Toggles the relay whenever the input signal is
activated