Commissioning
English, Revision 07, Date: 07.03.2018
42
4.10 (F) Error Logger
In order to identify errors during commissioning or operation the steering controller of-
fers two options. The first priority is the more universal data logging, described in sec-
tion 4.8 on page 39, secondly we have the error logger, described below.
In order to run the error logger
it is not necessary
to connect a PC / laptop during
operation. In case of error it is sufficient to connect the PC / laptop subsequently, as
the data remains stored inside the steering controller until it is switched off. The PC /
laptop can retrieve the required data via a terminal software. However, always the
same variables will be recorded (see Table 31 on page 43) at the time of a transponder
position impulse. This limits the possibility of troubleshooting for positioning and it only
works together with a transponder system.
To record data button
for Error logger in the main menu has to be pressed first. Then
the following window will open.
Figure 20
Screenshot: (F) Error Logger
Then select
Hyperterminal
->
Transfer
->
Capture Text
, afterwards name the
file and start recording with Hyper Terminal.
W
Nominal ve0,5
meters / second
s
Nominal velocity -0,1
meters / second
S
Nominal velocity - 0,5
meters / second
Space bar
Nominal velocity = 0
meters / second
+
Increase brake (if available in the selected
vehicle model)
-
Decrease brake (if available in the selected
vehicle model)
Key
Description
Unit
Table 30
Test Monitor: Input Options (part 2 of 2)
Please press spacebar to start logging !
[ESC] -> back/cancel