Commissioning
English, Revision 07, Date: 07.03.2018
30
4.2.2
Parameter Settings
The following parameter settings are required. Adapt the COM-Port, if necessary (see
below):
If you use another port than COM1 with Hyper Terminal, change the port in the follow-
ing way:
1.
In the file menu select menu item properties (or click on the cor-
responding icon
). The window shown to te right opens.
2.
Choose the corresponding port from the submenu connect and
confirm with
. Save the modified values, if an appropriate
message appears when quitting Hyper Terminal.
4.3
Using the Terminal Program
Starten Sie HyperTerminal auf dem PC und verbinden Sie den entspre-
Start Hyper Terminal on your PC and connect the corresponding COM
port to the connector "Terminal" on the control unit HG 61430.
Switch on control unit HG 64130 and wait until the last message from the operating
system is visible. Subsequently fill in code
314159
and confirm with
abgeschlos-
sen werden. The following menu will be displayed:
Terminal Settings Monitor Program
Baud rate
115200 Baud
Also possible: 9600, 19200, 38400 und 57600
Baud
Terminal emulation
ANSI
Terminal
24 lines, 80 columns
Parity
None
Datenbits
8
Stop bits
1
Flow control
None
PC interface (port)
COM1
(may differ in cases, see below)
Table 9
Terminal settings for the monitor program