46
*MVC8, *DVC8 W
IRING
D
IAGRAM
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
H
IG
H
V
O
LTA
G
E
!
D
IS
CO
NNE
CT
AL
L
PO
WER
BE
F
O
RE
SE
R
V
IC
IN
G
OR
IN
S
T
A
LLI
N
G
TH
IS
UNI
T
.
M
U
LTI
P
L
E
PO
WER
S
O
U
RCE
S
MA
Y
BE
PR
E
S
EN
T
. F
AIL
U
RE
TO
DO
SO
MA
Y
CAU
S
E
PR
O
P
E
R
T
Y
DAM
AG
E
,
P
E
RS
O
NAL
INJ
URY
OR
DE
AT
H
.
TO +VDC
TO
MICRO
TO
R
GND (4)
+ VDC (1)
RX (2)
TX (3)
CIRCULATOR
INDOOR
AIR
BLWR
RD
GY
BL
BK
PROPERLY POLARIZED
HUMIDIFIER
GND
PROTECTION DEVICE
BURNER COMPARTMENT
POWER SUPPLY WITH
LINE
RD
TO
C
BK
RD
DISCONNECT POWER
IGNITER
FLAME SENSOR
INTEGRATED CONTROL MODULE
POWER BEFORE
BR
YL
TERMINAL
HI
BL
OR ORANGE
MVH (14)
PM
ECM MTR
HARNESS
NO
24 VAC
HI VOLTAGE FIELD
115kBTU MODELS
AUTO RESET PRIMARY
LIMIT CONTROL
BEFORE SERVICING.
PS1 (2)
3
YL YELLOW
CIRCULATOR
BK
BR BROWN
BK
OVERCURRENT
24V HUM.
0140F00818 REV. B
IGNITER
115 VAC/ 1
BLOWER COMPARTMENT
24
BK
PM
WH WHITE
BK
INDUCED
DRAFT
BLOWER
EAC
C
3
BL BLUE
115 VAC
INDUCTOR COIL
WH
YL
GND
5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST
RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE
IN STANDBY (NO THERMOSTAT INPUTS)
Ø /60 HZ POWER SUPPLY WITH
TO 115VAC/ 1
BK BLACK
DEHUM
INTEGRATED CONTROL MODULE
GND
24V HUM.
2
WH
HOT
SURFACE
IGNITER
MVC (8)
NEUTRAL
DOOR
LOW FIRE PRESS.
SWITCH
4
3
2
CHASSIS GROUND
WH
VAC
GND
LOW VOLTAGE (24V)
2 CIRCUIT
CONNECTOR
HUM
HI VOLTAGE (115V)
OVERCURRENT
PSO (7)
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE
USED WHEN SERVICING.
ONLY
C
AIR CLEANER
TWO STAGE
GAS VALVE
(HONEY WELL)
DISCONNECT
HIGH FIRE
PRESS. SWTICH
INDOOR
HUMIDIFIER
Ø /60 HZ
PK PINK
N
WH
MANUAL RESET ROLLOUT
LIMIT CONTROLS
IND LO
40 VA
AUTO RESET AUXILIARY LIMIT
CONTROLS
YL
JUNCTION
BLWR
PU PURPLE
CIRCULATOR
BLOWER
R
1
GND
JUNCTION BOX
SWITCH (TEMP.)
NEUTRAL
115kBTU MODELS
BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
C
LINE
BK
4
NEUTRAL
POLARIZED AND
C
FS
2
PLUG CONNECTION
DISCONNECT
PU
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH
WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT
LEAST 105°C. USE COPPER CONDUCTORS ONLY.
RD
INTEGRATED CONTROL
PROT. DEVICE
HIGH FIRE
PRESSURE SWITCH
ONLY
W1
INTERNAL TO
70kBTU,90kBTU,
NO
EQUIPMENT GND
MVL (13)
O
SERVICING. WIRING
WH
YL
ID BLOWER TWO-STAGE PRESSURE
SWITCH ASSEMBLY
5
GND (5)
BK
IND HI
IGN
PK
HLO (10)
70kBTU,90kBTU,
NOTES:
PU
L
AIR
WH
MANUAL RESET ROLLOUT LIMIT
CONTROLS
Y1
GY GRAY
ELECTRONIC
RD RED
Y2
RD
NEUTRAL
1
HLI (1)
WH
SWITCH
AUTO RESET PRIMARY
LIMIT CONTROL
NO
WH
TRANSFORMER
MUST BE PROPERLY
BL
OR
OVERCURRENT PROTECTION DEVICE
GN
2
GROUNDED.
LOW VOLTAGE FIELD
W2
WARNING:
FIELD GND
FIELD SPLICE
SWITCH (PRESS.)
WH
115
NEUTRAL
BLWR
JUNCTION BOX
GND
1
AND GROUNDED.
BK
GAS
VALVE
24V THERMOSTAT CONNECTIONS
PU
INDUCTOR COIL
TH (4)
C
HI
1
24V HUM.
TO UNIT MUST BE
VAC
G
C
TR (11)
GR
GN GREEN
HOT SURFACE
FLAME
SENSOR
PS2 (12)
LOW FIRE
PRESSURE
SWITCH
1
INTEGRATED CONTROL MODULE
COLOR CODES:
L
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO
N.E.C. AND LOCAL CODES.
YL
3
WIRING TO UNIT
NO
NEUTRAL
N
BR
WH
40 VA
TRANSFORMER
ID
TO
MICRO
WARNING:DISCONNECT
PU
AUTO RESET
AUXILIARY
LIMIT CONTROL
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
FUSE 3 A
2
HEAT OFF
DELAY
24 V
3 A
BL
G
12
2
UNUSED
4
5 CIRCUIT CONNECTOR
4 CIRCUIT MOTOR
CONNECTOR
DIP SWITCHES
4
1
FUSE
15
6
ADJUST
5
HEAT
LINE
2
RD
DEHUM
2
9
14
Y2
3
HUM
1
YL
NEUTRAL
11
EAC
TWO-STAGE
INTEGRATED
CONTROL
MODULE
8
WH
24 V THERMOSTAT CONNECTIONS
W1
2ND STG DLY
RD
R
BL
2
Y1
13
1
3
T-STAT
5
BR
BK
DELAY
7
1
C
W2
3
FS
4
YL
YL
DIAGNOSTIC
LED'S
RD
O
DEHUM
10
OR
SEE
NOTE 5
COOL
GN
RD
BL
BK