45
A
IR
F
LOW
D
ATA
D
IP
S
WITCHES
NOTE:
Airflow data shown applies to non-communicating mode operation only. For a fully communicating
system, please see the outdoor unit’s installation instructions for cooling and pump heating airflow data. See
ComfortNet™ System - Airflow Consideration
section for details.
1
2
3
4
5
6
7
8
9
10
9 0 secon ds
O FF
OFF
-- -
---
---
- --
---
---
- --
---
120 se cond s
O N
OFF
-- -
---
---
- --
---
---
- --
---
150 se cond s*
O FF
O N
-- -
---
---
- --
---
---
- --
---
180 se cond s
O N
O N
-- -
---
---
- --
---
---
- --
---
1 -Stage T-stat
---
---
O FF
---
---
- --
---
---
- --
---
2-S ta ge T-S ta t
---
---
ON
---
---
- --
---
---
- --
---
5 -Min Delay
---
---
-- -
O FF
---
- --
---
---
- --
---
Auto Del ay
---
---
-- -
ON
---
- --
---
---
- --
---
Bu s B IAS
BIA S
ON*
O N*
-- -
---
---
- --
---
---
- --
---
TERM
Bus Te rmin ation
---
---
ON*
---
---
- --
---
---
- --
---
A
O FF
OFF
-- -
---
---
- --
---
---
- --
---
B
O N
OFF
-- -
---
---
- --
---
---
- --
---
C
O FF
O N
-- -
---
---
- --
---
---
- --
---
D*
O N
O N
-- -
---
---
- --
---
---
- --
---
No rma l*
---
---
O FF
O FF
---
- --
---
---
- --
---
1 0%
---
---
ON
O FF
---
- --
---
---
- --
---
-10%
---
---
O FF
ON
---
- --
---
---
- --
---
No rmal
---
---
ON
ON
---
- --
---
---
- --
---
A*
---
---
-- -
---
OFF
O FF
---
---
- --
---
B
---
---
-- -
---
O N
O FF
---
---
- --
---
C
---
---
-- -
---
OFF
ON
---
---
- --
---
D
---
---
-- -
---
O N
ON
---
---
- --
---
A
---
---
-- -
---
---
- --
O FF
OFF
- --
---
B*
---
---
-- -
---
---
- --
ON
OFF
- --
---
C
---
---
-- -
---
---
- --
O FF
O N
- --
---
D
---
---
-- -
---
---
- --
ON
O N
- --
---
Disa ble d*
---
---
-- -
---
---
- --
---
---
O FF
Un used
E na bled
---
---
-- -
---
---
- --
---
---
ON
Un used
---
Not ap plica ble
(*Indi cates fa cto ry se ttin g)
Hea ting
Spee d Tap
DEHUM
S5
S4
DIP Swi tch No.
The rmo sta t
Setup
S1
S2
Sw itch
Bank
Purpose
He at OFF
De lay
Function
Co oling
Spee d Tap
A djust Taps
S3
Ra mping
Pro fi les
*DVC81005C***
*DVC80805C***
*DVC80603B***
*MVC81005C***
*MVC80805C***
*MVC80604B***
To set airflow:
C ------- 7.5 min/82% 60 sec/100%
A ------- -------- 60 sec/100%
TAP 1 2 3 4 5 6 7 8
To set Comfort Mode:
B ON OFF ON OFF ON OFF ON OFF
C OFF ON OFF ON OFF ON OFF ON
B ------- 30 sec/50% 60 sec/100%
D ON ON ON ON ON ON ON ON
D 30 sec/50% 7.5 min/82% 30 sec/50%
Select desired Comfort Mode profile
(see profiles above). Set switches 5 and 6 to the appropriate
ON / OFF positions.
A OFF OFF OFF OFF OFF OFF OFF OFF
Model Tap Low Stage High Stage Low Stage High Stage
Cool Cool Heat Heat
Cool Adjust Profile Heat
Selection Selection Selection Selection
Switches Switches Switches Switches
Profiles Pre-Run Short-Run OFF Delay
(1) Select model and desired
high stage cooling airflow. Determine the corresponding tap
( A, B, C, or D ). Set dip switches 1 and 2 to the appropriate
ON / OFF positions. (2) Select model and desired high stage
heating airflow. Determine the corresponding tap ( A, B, C, or
D ). Set dip switches 7 and 8 to the appropriate ON / OFF
positions. (3) Select the airflow adjustment factor taps A and
D are 1; Tap B is +10%; Tap C -10%. Set dip switches 3 and 4
to the appropriate ON / OFF positions.
Speed Selection Dip Switches
390
520
650
780
A
B
C
D
600
800
1000
1200
735
805
875
935
1050
1150
1250
1350
520
715
910
1170
A
B
C
D
800
1100
1400
1800
945
1015
1085
1155
1350
1450
1550
1650
553
748
943
1203
A
B
C
D
850
1150
1450
1850
1085
1155
1225
1260
1550
1650
1750
1800
390
520
715
910
A
B
C
D
600
800
1100
1400
875
945
1015
1085
1250
1350
1450
1550
520
715
910
1170
A
B
C
D
800
1100
1400
1800
1050
1120
1190
1260
1500
1600
1700
1800
520
715
910
1175
A
B
C
D
800
1100
1400
1800
1210
1225
1245
1260
1725
1750
1775
1800