Programming the Tekna Plus
monitors:
SE
AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED DOOR PANEL
PROGRAMMING THE MONITORS
From sound module:
L
ocate the SW2 DIP switch situated on the top left-hand side of the back of the EL632 PLUS
module
P/T
and set number 2 to ON. The door panel will reproduce a sound to advise that the system has entered
into programming mode.
In systems with more than one door panel, the programming process shall be done on the master door panel only.
Important:
.
To perform this programming, the monitor's SW2 DIP switches should be set to
OFF
From coded module:
Press the key button three times and then enter the administrator pin he
will
t
module
emit tones
,
:
Each apartment must only have one master unit; if there are parallel units, whether monitors or telephones, they must be
configured as slaves.
Make a call to check that the monitor has been successfully programmed. Programme the other
telephones in the same way.
Once the programming has finished, set the
programming switch to OFF
sound module
or press the
key if the programming is from coded module. If this is not done, the door panel will emit tones to
indicate that the system is still in programming mode
.
(programming from sound module)
To programme the monitor from a general entrance door panel (if any), see p.
.
86
0
1
85
Important:
Programming from coded module:
- With EL632 PLUS sound module V03 or later / EL632 PLUS P/T with V05 or later.
- With N3301/AL or NX3301
V03 or later.
access control module
(1)
2
7
1 8
Key key key administrator pin.
Bear in mind the number of digits in the configured code (factory setting 2718 = 4).
(1)
C
Switch off the monitor to be programmed
.
Once switched off, press the door release push button.
While keeping the door release push button pressed, switch on the monitor.
To show that the system is ready for programming, the door panel will emit a number of tones
and an image will appear on the monitor, at which point the door release push button can
be released. To establish audio communication with the door panel, lift the handset.
To programme the monitor as
, press button
for 3 seconds
Master
.
M
S
SI
SV
To programme the monitor as
, press button
once, and the status LED will blink green once.
Slave
1
Continue successively to
, pressing button
four times, with the status LED blinking green
Slave 4
four times.
To programme the monitor as
, press button
and the status LED will blink green
Slave with intercom
once.
To programme the monitor as
, press button
and the status LED will blink green
Slave without video
once. If button
is pressed again, the monitor will return to being programmed as
,
Slave with video
and the status LED will blink green twice. The door panel video will be displayed during a call depending
on whether the monitor has been programmed as: Slave with video or Slave without video.
Enter the code of the monitor to be programmed, followed by the key button.
At this moment the door panel will reproduce a sound and the monitor led will
blink.
0
1
Содержание NEXA Series
Страница 4: ......
Страница 5: ...Standalone access control...
Страница 23: ...Access control combined with Nexa door panels...
Страница 54: ...Coded door panel...
Страница 98: ...Coded panel with display...