44
INSTALLATION OF THE POWER SUPPLY UNIT
DIN 46277
3,5 x 45
DIN-7971
3,5 x 45
DIN-7971
Replace the protective cover once the input terminals have been wired.
Please note that current regulations stipulate that the power supply must be protected
by a circuit breaker. Connect the FA-Plus power supply unit to the earth connection.
To install the power supply unit directly on the wall, drill two holes of Ø6mm and insert the wall
plugs. Fix the power supply unit using the specified screws.
The power supply unit can be installed on a DIN 46277 rail by applying slight pressure.
To remove the power supply unit from the DIN rail, use a flat screwdriver to lever it off,
as shown in the drawing.
The FA-Plus/C model requires 6 elements on the DIN rail and the FA-Plus model 10.
I
MPORTANT: the maximum number of units that can be connected to FA-Plus/C and FA-Plus power supply unit is 10 and
50, respectively.
Install the power supply unit in a dry and protected place free from the risk of water leaks or sprays.
To prevent electric shock, do not remove the protective cover of the primary or handle the wiring.
The fitting and handling of this device must be carried out by authorised personnel in the absence of electrical current.
To avoid damage, the power supply unit must be firmly secured in place.
FA-PLUS and FA-PLUS/C power supply installation drawing:
INSTALLATION OF THE LOCK RELEASE
Lock release
If the lock release is to be fitted to a metal door, use
a Ø3.5mm drill bit and thread the hole made.
For wooden doors, use a Ø3mm drill bit.
M 4 x 8
DIN-7972
DIN-963
IMPORTANT: the access control module is supplied with two varistors. If
connecting an AC lock release to one of the outputs, fit the
varistor supplied directly to the lock release terminals to
ensure that the module functions correctly.
DOOR PANEL OPERATION
Description of door panel operation
In addition to the operating mode of the access control module described on p. 10, it is possible to make calls to
telephones and/or monitors in the installation using the door panel's corresponding EL610 button module.
PROGRAMMING THE DOOR PANEL
Programming fields
To check the programming
fi
elds of the door panel with access control, see p. 11-21.
AUDIO AND VIDEO DOOR ENTRY SYSTEM - ACCESS CONTROL