![GOK Leak Check LPG PRO Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/gok/leak-check-lpg-pro/leak-check-lpg-pro_assembly-and-operating-manual_2239118024.webp)
24 / 48
Artikel-Nr. 27 105 50 a
EN
DISPOSAL
To protect the environment, our electrical and electronic appliances may not be
disposed of along with household waste.
The commercial customer (owner) is obligated to properly dispose of the electronic
devices of the “GOK” brand delivered to them at their own expense in accordance with
the provisions in the Elektro- und Elektronikgerätegesetz (ElektroG) [Electrical and
Electronic Equipment Act] after termination of the use thereof. In this way, GOK
Regler- und Armaturen-Gesellschaft mbH & Co. KG is exempt from the obligations
under Sec. 10 para. 2 ElektroG and third-party claims connected thereto.
If the commercial customer fails to contractually obligate third parties to whom they
forward our electronic devices to assume the disposal obligation and to pass on
obligations, this customer shall be obligated to take back the supplied electronic
devices at their own expense and to properly dispose of them in accordance with the
statutory provisions after termination of the use thereof.
Our registration number for the electrical old appliances register (EAR) is:
WEEE-Reg.-No. DE 78472800.
TECHNICAL DATA
Power supply
Wall plug transformer (included with delivery)
Lead acid battery
12V, 1.2Ah, maintenance-free, VDS mark
Power consumption from wall plug
transformer
Type 45 – 110mA at 15V plus the charging current
for battery (max. 500mA)
Dimensions
190mm x 105mm x 56mm without plug
Housing
Euro aluminium housing
Connection plug (wall plug transformer) 2-pole plug (5,5mm x 2,1mm)
Connection plug, power supply for
printer
2-pole plug (4,75mm x 1,7mm)
Connection plug RS-232 interface for
external printer
9-pole Sub-D plug (like PC-COM interface)
Pressure measurement range
0 ... 200mbar, overload-proof to 1bar
Accuracy of pressure measurement at
20°C
140 ... 160mbar : +/- 2mbar
Ambient temperature during operation
15°C … 40°C, ideally 15°C … 25°C
Ambient temperature during storage
10°C … 30°C, the higher the temperature,
the faster the battery will discharge