Caramatic BasicTwo
4 / 12
part no. 02 018
51d
*Qualified personnel within the meaning of these technical regulations (work sheet
DVGW G 607 [A] or G 608 [A]) are in particular those qualified personnel recognised by the
DVFG who can, on the basis of their training, knowledge and experience gained during
practical activity, guarantee that they will carry out the inspection properly.
DESIGN
Central regulator
Changeover regulator
Inlet connections
Connection port
Pressure gauge
Breather without figure
Rotary knob for the
operation of reserve
cylinder
Connection block for de-icer
Outlet connection for
+
medium pressure hose
assembly (rubber with textile
lining; resistant to cold
temperatures reaching -30 °C;
hose dimension 6.3 x 3.5 mm x
400 mm)
to connect the two regulators brass connections, stainless steel compressive sleeves
connection G 3/8 lh nut x G 3/8 lh nut
to connect the system to the piping, brass connections, stainless steel compressive
sleeves, connection G 1/4 lh nut x RVS 8
FUNCTION DESCRIPTION
Central and changeover regulator
At the changeover regulator you can use a rotary
knob to determine which gas cylinder should be
used as the reserve cylinder or the operating cylinder.
If, for example, the arrow on the rotary knob is
switched to “Reserve”, the gas from the cylinder with
the central regulator is given priority. The gas
cylinder with the changeover regulator then serves
as the reserve cylinder. If, on the other hand, the arrow
on the rotary knob is switched to “Operation”, the
gas is taken from the cylinder with the changeover
regulator and the gas cylinder with the central
regulator serves as the reserve cylinder.
Always turn the rotary knob as far as it goes towards “Operation” or
“Reserve”!
The operating cylinder determined by the rotary knob is emptied first.
The Caramatic BasicTwo two-cylinder system then automatically switches to the previously