R
4
3.
DELIVERY UNITS / DELIVERY CONTENTS
A complete Fox up ventilation unit consists of an EPS wall duct and a fan unit for insertion into the wall duct. The fan unit
consists of a reversible fan (12 V/DC) and a ceramic heat accumulator for heat recovery.
Air is fed into the room through a design plate with filter insert, and carried to the outside through a weatherproof protective
hood.
The unit is operated via an electronic control system with control panel, and up to six ventilation units (3 x delivery, 3 x
extraction) can be controlled by the electronic control system. The electronic system is installed in a double-cavity wall box for flush-moun-
ted fitting.
The following delivery units are available for the various installation steps:
•
Fox up-GP-Design
, item no. 1145200: basic package consisting of wall duct (500 mm long), fan unit, inner plate, weatherproof protec-
tive hood and electronic control system with hollow-wall flush-mounted box.
•
Fox up-EP-Design
, item no. 1145201: supplementary package consisting of wall duct (500 mm long), fan unit, inner plate and weather-
proof protective hood.
•
Fox up-Shell set 500 mm
, item no. 1145210: shell set consisting of wall duct (500 mm long) and hollow-wall flush-mounted box.
•
Fox up-Shell set 1000 mm
, item no. 1145211: shell set consisting of wall duct (1000 mm long) and hollow-wall flush-mounted box.
•
Fox up-Shell set 500 mm,
item no. 1145212: shell set consisting of wall duct (500 mm long)
•
Fox up-Shell set 1000 mm
, item no. 1145213: shell set consisting of wall duct (1000 mm long)
•
Fox up FMS-GP-Design
, item no. 114220: final assembly basic package consisting of fan unit, inner plate, weatherproof protective
hood and electronic control system.
•
Fox up FMS-EP-Design
, item no. 1145221: final assembly supplementary package consisting of fan unit, inner plate, weatherproof
protective hood and electronic control system.
Fox up ventilation unit complete
1.
Weatherproof protective hood
(air inlet/outlet opening on outside)
2.
EPS wall duc
t
3.
Design valve
(air inlet/outlet opening on room side)
4.
Fan uni
t (incl. ceramic heat accumulator and filter insert)
5.
Control panel / electronic control system
Содержание Fox-Up
Страница 26: ...R 24 Maintenance work carriedoutby 8 MAINTENANCEREPORT FILTERCLEANING Maintenancereport...
Страница 28: ...R 26...
Страница 52: ...R 50 Wartungsarbeiten ausgef hrtdurch 8 WARTUNGSPROTOKOLL FILTERREINIGUNG Wartungsprotokoll...
Страница 54: ...R 52...
Страница 78: ...R 76 Onderhoudswerk uitgevoerddoor 8 ONDERHOUDSVERSLAG FILTERREINIGING Onderhoudsverslag...
Страница 80: ...R 78...
Страница 104: ...R 102 Travaux de maintenance Effectu spar 8 ONDERHOUDSVERSLAG FILTERREINIGING Rapportdemaintenance...
Страница 106: ...R 104...
Страница 107: ...R www glt de www ventilairgroup com...