GLP
German Light Products GmbH
(instruction version 1.33 / from software version 1.53)
8
a) Camlock system: This system allows you a fast and efficient setup of
clamps. Attach the two camlocks to designated position (C1 and C2) on
the bottom side of the case and close the locks by turning them 90°.
Verify the secure fit of the camlock system. The clamps themselves are
directly attached permanently on the camlocks.
90°
b) Use two clamps direct on the bottom side of the
Y
Y
P
P
O
O
C
C
7
7
0
0
0
0
C
C
M
M
Y
Y
to
mount the unit on a truss (each two opposite threads A1 -A4 or A2 - A3,
use screws M10 max. length 50 mm). Distances, diameters and
positions can also been seen on the printing on the bottom plate of the
system.
2.2 Secure
the
Y
Y
P
P
O
O
C
C
7
7
0
0
0
0
C
C
M
M
Y
Y
Regardless of the rigging of the
Y
Y
P
P
O
O
C
C
7
7
0
0
0
0
C
C
M
M
Y
Y
you have to use a stipulated
safety wire. Therefore you have to pull the safety wire through to two provided
holes on the bottom side of the fixture and connect it with the truss-support. Pay
attention to a safe and proper fastening. Install a safety wire that can hold at least
10 times the weight of the fixture. Never use the carrying handles for this purpose.
2.3 Connections
2.3.1 Power
supply
Electronic ballast with:
~90 - 260 Volt, 50 - 60 Hz, earth contact type plug - Powercon
Connected load 1000W
<=>
4.5 A (blind current compensation).
Please see printing on the case for the right electronic supply!
2.3.2 DMX
USITT DMX 512 Standard input/output, 3 pole connectors.
[+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 1