GLP
German Light Products GmbH
(instruction version 1.33 / from software version 1.53)
27
Lamp ON
Shutter open
Channel 17
240..255 F0..FF 94..100
Lamp OFF 1
Special channel Lamp OFF 1
if Shutter channel = closed DMX ´000`
(min. 3 sec.)
Channel 31 and
Channel 17
230..249
000
6E..9F
00
92..97
000
Lamp OFF 2
Special channel Lamp OFF 2
if Shutter channel = DMX ´240..253`
(min. 3 sec.)
Channel 31 and
Channel 17
249
240..253
9F
F0..FD
97
94..98
Reset 1
Head only (PAN/TILT)
Channel 31
250..253 FA..FC
98..99
Reset 2
All functions
Channel 31
254..255 FD..FF
100
5 Changing the Lamp
For a frictionless operation pleas read this chapter carefully and follow all instructions.
5.1 Safety
Regulations
•
Pull out the main plug!
•
Wait min. 20 minutes after the last operation to cool down the fixture.
•
For a safe and convenient operation the head can be locked in various
positions. Please unlock the head before switching on again.
•
Don’t touch the bulb of the lamp with bare fingers (this can cause damages).
•
Before you put the
Y
Y
P
P
O
O
C
C
7
7
0
0
0
0
C
C
M
M
Y
Y
into operation close the casing, otherwise
your retina can be hurt!
5.2 Realize the Lamp Change
1. Pull out the main plug!
2. The lamp can be changed in a very comfortable way directly from the backside
of the case without opening the head.
4x