Page 23
SmartOne C User Manual
Confidential & Proprietary Information
9100-0410-01 R2.4
TYPE OF INPUT
NOTE:
The Type of Inputs section is applicable for SmartOne Solar only.
For Input State Capture using SmartOne C devices, refer to description in the Input Status Changed Message
Section and Undesired Input State Message Sections.
OPTIONS TAB
• Device Turned On Message -
The SmartOne is configured to send a Device Turned On Message on
Power-up by default.
• Interval for Replace Battery Message -
The SmartOne can be configured to transmit a Replace Battery
message based on a low battery condition.
○
To turn this feature on, select the Enabled checkbox.
○
Configuration range extends from 0 to 45 days in steps of a day. The default is 1 day.
○
The SmartOne will detect low battery conditions while at least 100 more messages can still be transmitted.
• Interval for Diagnostic Message -
The SmartOne can send a diagnostic message with information on the
diagnostic status of the device.
○
To turn this feature on, select the Enabled checkbox.
○
The diagnostic message includes battery status, GPS average search time, GPS fails and number of
transmissions since last diagnostic message.
○
Transmit interval of diagnostic messages with a transmission rate from 1 to 45 days. The default is 30 days.
• SmartOne Solar Only -
This section is applicable to configuring SmartOne Solar devices only; refer to the
SmartOne Solar User Manual for details.