Model P53 pH/ORP Analyzer (universal-mount 1/2 DIN)
Rev. 6-501
10
T A B L E O F C O N T E N T S ( c o n t i n u e d )
SECTION 3
ADJUSTING DISPLAY CONTRAST
............................................................. 37
SECTION 4
ANALYZER CONFIGURATION
4.1 Selecting LANGUAGE to Operate Analyzer.......................................... 37
4.2 Configuring Sensor Characteristics:
SELECT SENSOR Type .................................................................. 38
Select DISPLAY FORMAT ............................................................... 39
SELECT BUFFER Set for pH Calibration ........................................ 39
Select PURE H2O COMP (for special applications). ....................... 40
SET ISO POINT (isopotential for special Differential pH sensor) ........ 41
SET FILTER Time.......................................................................41-42
Select PULSE SUPPRESS (on/off).................................................. 42
ENTER NOTE (top line of MEASURE screen)............................42-43
Select TEMP ELEMENT Type ....................................................43-44
4.3 SET
°
C OR
°
F (temperature display format) ....................................44-45
4.4 Configuring Analog Outputs (1 and 2):
SET PARAMETER (representation) ...........................................45-46
SET 0/4 mA and 20 mA VALUES (range expand) ......................46-47
SET TRANSFER Value (mA) ........................................................... 47
SET FILTER Time............................................................................ 48
Select SCALE 0 mA/4 mA (low endpoint) ........................................ 48
4.5 Configuring Relays (A, B, C, and D):
SET PARAMETER (representation) ...........................................49-50
SET FUNCTION Mode (alarm, control, timer or status)..............50-51
SET TRANSFER Mode (relay on or off) .......................................... 51
ACTIVATION (configuration values) ...........................................52-53
4.6 SET PASSCODE (feature enabled or disabled) ................................... 54
4.7 Configuration Setting Summary (ranges/choices and defaults) .......55-56
SECTION 5
ANALYZER CALIBRATION
5.1 Important Information
Calibrate Periodically ....................................................................... 57
Temperature-corrected pH Measurement ........................................ 57
5.2 pH Calibration:
2 POINT BUFFER Method..........................................................58-60
1 POINT BUFFER Method..........................................................61-62
2 POINT SAMPLE Method..........................................................63-65
1 POINT SAMPLE Method..........................................................65-67
5.3 ORP Calibration ...............................................................................67-69
5.4 Analog Outputs (1 and 2) Calibration...............................................69-70