Wireless dimming actuator, 4-gang
Figure 4: Connection example with two parallel outputs each
Do not connect any LED lamps or compact fluorescent lamps to outputs switched in par-
allel.
Do not connect electronic and inductive Transformers together to outputs switched in par-
allel.
■
Connect loads as shown in the wiring example (Figure 4).
Presetting the operating mode
Each load output has an operating mode switch with which the dimming principle is set.
Figure 5: Operating mode switch
Switch position
Function/connectable loads
PC
Dimming principle and parameter set with eNet Server.*)
R,L,C
Universal
Automatic calibration to the load, dimming principle, leading
edge phase control or trailing edge phase control. Connec-
tion of incandescent lamps, HV halogen lamps, electronic
transformers with halogen or LED lamps or dimmable induct-
ive transformers with halogen or LED lamps.
HV-
|
LED leading edge
phase control
Setting for incandescent lamps, HV halogen lamps, elec-
tronic transformers with halogen or LED lamps that can be
dimmed according to the trailing edge phase control principle
or dimmable HV-LED or compact fluorescent lamps that can
be dimmed according to the leading edge phase control prin-
ciple. The connection of inductive transformers is not permit-
ted.
HV-
{
LED trailing edge
phase control
Setting for incandescent lamps, HV halogen lamps, elec-
tronic transformers with halogen or LED lams that can be
dimmed according to the trailing edge phase control prin-
6 / 19