Wireless dimming actuator, 4-gang
–
Switch-off warning
–
Operation locks
–
Continuous on, Continuous off
–
Hotel function
–
Run-on time
–
Light control
Supplementary functions with eNet Server:
–
Fully encrypted radio transmission (AES-CCM) from eNet Server software version 2.0
–
Update of the device software
–
Reading of error memory
Behaviour in case of bus voltage failure and return
If the bus voltage fails, the actuator switches off. The response to bus voltage return can be
parameterised with eNet server. Default setting: Off.
3
Operation
When operating with the eNet Server, operation and signalling could vary from what is de-
scribed here.
Operation with radio transmitters
Operation is with radio transmitters, please observe the radio transmitter instructions.
Operation with Prog button
Switching the light
■
Press Prog button briefly.
The light switches on or off at the saved switch-on brightness.
Status LED A1..A4 (4) lights up: output is switched on.
Status-LED A1..A4 (4) off: output is switched off.
Save switch-on brightness
■
Set the light of the corresponding output with a connected radio transmitter to the required
brightness.
■
Press Prog button of the corresponding output for longer than 4 seconds.
The output switches off briefly and then switches on again to the new switch-on bright-
ness.
Switch-on brightness of the corresponding output is saved.
Alternatively, the switch-on brightness can be saved with a radio transmitter, e.g. wall
transmitter.
4
Information for electrically skilled persons
4.1 Fitting and electrical connection
DANGER!
Mortal danger of electric shock.
Before carrying out work on the device or load, disengage all the corresponding cir-
cuit breakers. Cover up live parts!
2 / 19