GIMA SpA
DIATERMO MB250 – DIATERMO MB400
MA303IGBa-19-03-2007 Manuale
d’Istruzioni / Instruction’s Manual
30
code description
DIATERMO
MB250
DIATERMO
MB400
310-140-20
Bipolar Forceps (20cm TIP 2mm)
310-142-10
Curved Bipolar Forceps (20cm TIP 1mm)
310-142-20
Curved Bipolar Forceps (20cm TIP 2mm)
310-180-10
Angled Bipolar Forceps (20cm TIP 1mm)
310-180-20
Angled Bipolar Forceps(20cm TIP 2mm)
310-182-10
Angled Bipolar Forceps (20cm TIP 1mm)
310-185-10
Curved Bipolar Forceps (20cm TIP 1mm)
310-510 Bipolar
Forceps
(20cm)
310-550
Bipolar Electrode (20cm)
310-590
Bipolar Electrode (20cm)
320-134-20 Monopolar
Forceps
330-160 Surgical
Scissors
755VL
Disposable handle with finger switchesi
/5
/5
CB462
Silicone Bipolar Cable 3m
F4243
Reusable Handle with finger switches
/1
/1
F4814
Reusable handle without finger switches
F7520
Electrode cleaning sponge size 47x50mm
/1
/1
F7915
Conductive rubber neutral electrode
F7920 Disposable
split neutral electrode
/5
/5
F7930
Conductive rubber split neutral electrode
MA303 Instruction
Manual
/1
/1
/pcs= STANDARD
= OPTIONAL
1.3 GENERAL DESCRIPTION
DIATERMO MB250
and
DIATERMO MB400
are high frequency electro-surgical equipments suited to deliver current for
monopolar cut, coagulated cut (with different levels of coagulation), in monopolar modality and cut and coagulation in bipolar
modality. In the bipolar modality, for the coagulation, the automatic system of activation/not-activation can be started when the
coagulation is happened (AUTOSTOP – AUTOSTART).
A total of ten different modes of use and levels of power, can be stored and recalled for the use simply. It is possible to use
either single plate neutral reference electrodes or electrodes with split conductive zone so to watch the stability of the plate to
patient impedance during the surgical intervention.
Control of the units is via front panel keys and display; mains inlet is located on the rear panel.
The units have automatic control systems that, monitoring the internal parameters, signal the possible damages/errors that are
found.
The operational parameters that are used are constantly stored so that, every time the unit is switched on or the operative
method is changed, the last selected parameters are recalled.
The level of the emission sound can vary; every operator can choose his own level according to the environmental conditions
of working.
The units can work either through holder-handles with or without pushbuttons with double foot switch command.
It’s possible to connect bipolar forceps to the unit for the bipolar functions.