background image

   

 

12

 

 

just turning, then press 

 

  button to set the information, and then press 

  to return. 

(4) Contents explanation: 

     

Backlight:

  0-99  seconds,  the  time  of  turning  on  the  backlight,  and  the  backlight  normally  off 

when it sets 0 second. 

     

Contrast:

 00-20, set the corresponding number according to different types of instrument. 

     

Language: 

English, Chinese, totally two types of language interface. 

     

Demo:

 ON, OFF, choose ON in demo when it does not need to be actual checked. 

8 The notice of the battery operating 

(1)  This  device  includes  hermetical  chargeable  lithium  battery,  which  needn’t  maintenance.  This 

battery  is  with  perfect  automatic  charge  and  discharge  circuit.  When  you  connect  power  supply 

adapter  with  alternating  current,  the  charge  will  be  start  automatically.  When  this  device  is  on,  an 

icon   

  is  displayed  on  top  right  corner  of  LCD  screen. 

  means  the  battery  is  on  charge.  The 

whole charge process needs four hours when it is exhausted.   

(2)  When  the  battery  is  full,  the  device  can  be operated for  one  hour,  when  the  battery  be  used  as 

power  supply,  An  icon  of  battery  will  be  displayed  in  the  LCD  screen  of  front  panel,  this  icon 

indicates power of battery. When the battery is power off, the device will turn off automatically; this 

setting is for avoiding permanent damage on battery caused by excessive discharge. 

(3) please charge the battery after power off. When this device be deposit for long time, the battery 

should be charge once every six months, this operation will prolong the use –pan of battery. 

(4) The icon of seven different state of power supply as following: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(5) If the battery is full, but the power of battery is exhausted within 10 minutes. Please change new 

battery. If the battery is can’t be charged, please change new battery. 

(6) When the icon   

  display on screen. Please charge the battery immediately, or the device will 

turn off. 

 

 

AC power is on (no battery) 

 

The battery is only power supply and its power is full. 

 

The battery is only power supply and its power is not full 

 

 

 

The  battery  is  only  power  supply  and  its  power  is 

exhausted. 

 

The battery is on charge 

Содержание 33257

Страница 1: ...Code 33257 CARDIOPOCKET ECG USER MANUAL ...

Страница 2: ... for details Please read the Manual very carefully before using this equipment These instructions describe the operating procedures to be followed strictly Failure to follow these instructions can cause measuring abnormality equipment damage and personal injury The manufacturer is NOT responsible for the safety reliability and performance issues and any monitoring abnormality personal injury and e...

Страница 3: ...rview 2 3 Principle and Caution 3 4 Technical specifications 4 5 Accessories 4 6 Installation 5 7 Operating Guide 8 8 The notice of the battery operating 12 9 Repairing and Maintenance 13 10 Troubleshooting 14 11 Key of Symbols 17 ...

Страница 4: ...ded by our company if the defibrillation time is over 5 s you should use one off chest electrode which can avoid the metal electrode burn patient s skin Please don t use it with electric stimulator at the same time if it is compulsory a professional technician must guide on the scene 1 2 Warnings Explosive hazard DO NOT use the Electrocardiograph in environment with inflammable gas such as some ig...

Страница 5: ...0 05 150Hz frequency response which is the world level also the equipment has advanced digital baseline drifting filter Alternating Current filter and Myo electricity disturbance filter The sampling rate of lead signal is 800Hz the closure frequency of low pass filter machine with guards against mixes folds is 3dB 220Hz The sampling rate is higher than the standard of not lower than 500Hz which ma...

Страница 6: ...tem coordinates the operation of print controlling equipment liquid crystal screen and keyboard driver it is responsible for the profile print driver controlling information demonstration keyboard management and some other control of CMS80 3 2 Caution 3 2 1 Observe the status of the patients and the instrument momentarily 3 2 2 Use the patient cable only to connect the patient and instrument 3 2 3...

Страница 7: ... provided by the factory It may damage this equipment if using the accessories with different models Power adapter Input AC 100 240V 50 60Hz Output DC 9V Attention User can choose the power cord according the request of local power net and also the safe standard Power supply adapter should be accorded with relevant regulation according to IEC60601 1 One lithium rechargeable battery DC 7 4V lithium...

Страница 8: ... 5 6 Installation 6 1 Sketch on each side and accessory Front view ...

Страница 9: ...d V4 V4 Fifth inter costal space at left mid clavicular line V5 Left anterior axillary line at the horizontal lever of V4 V6 Left mid axillary line at the horizontal lever of V4 Clean the positions around to which chest electrodes are to be attached with alcohol lay the ECG medical gel on dia 25cm area around the position and the edge of chest electrode cap press the suction bulb firmly attach the...

Страница 10: ...d skin Attention Tighten the knob after inserting the mainframe patient cable pin in the patient cable socket 6 2 3 Electrode connection definitions and color code Electrode Location Electrode Code Line Color Electrode Color Socket Number Right arm R Black Red 9 Left arm L Black Yellow 10 Left leg F Black Green 11 Right leg RF Black Black 14 Chest 1 V1 C1 White Red 12 Chest 2 V2 C2 White Yellow 1 ...

Страница 11: ...ing paper according to the illustration then clip them in the relevant position in paper fixer 3 Close the paper cabinet cover and protrudes 2cm in the top of the recording paper 7 Operating Guide 7 1 The instrument starts self checking after its turning on In the self checking process 7 2 The instrument will show the following state after self checking under DEMO mode ...

Страница 12: ...ning for example then press the button to switch the relevant information this column is read only The state and other indicator information are all read only Mode Conversion shows the mode conversion of the systemic lead it divides into Auto lead conversion AUTO and Manual lead conversion MANU Leading condition indication it will show NORM when the leads collecting signals normally and OVER when ...

Страница 13: ...tton as followings Press button to return after installing paper 5 Calibrating Press button to print a lmv standard voltage mark in order to observe the current sensitivity directly The LCD will display the following picture when in calibrating process In calibrating process Please Waiting English Interface Ending the Calibrating English Interface ATTENTION The calibrating process is operated auto...

Страница 14: ...trument records the twelve patient cables automatically three seconds ECG signal each patient cable Filter OFF 50Hz 60Hz 50Hz 60Hz totally five types of filter among them 50Hz and 60Hz denote the opening of 35Hz EMG filter ATTENTION Switching on the EMG interference filter will fall the range of the recorded R wave Speed 25mm s 50mm s totally two types of paper skipping speed mode System Manual En...

Страница 15: ...When the battery is full the device can be operated for one hour when the battery be used as power supply An icon of battery will be displayed in the LCD screen of front panel this icon indicates power of battery When the battery is power off the device will turn off automatically this setting is for avoiding permanent damage on battery caused by excessive discharge 3 please charge the battery aft...

Страница 16: ...t guarantees for one year and do not arbitrary disassembly Remove the electric plug when there is power cut the instrument must be kept cool and dry when it is unused for long time electrify the instrument every three months Inspect and maintain of Lead electrode 1 The state of leads can be checked by multimeter please check the leads according to following list If the resistance between electrode...

Страница 17: ...eck battery capacity The instrument has the function of protecting the electro circuit when the battery over discharged 2 Check the AC power voltage The instrument has the function of protecting the electro circuit when its overvoltage 3 Check AC interference check the knob on the plug of the patient cable The instrument has the function of protecting the electro circuit when over loading 10 2 AC ...

Страница 18: ... electrodes and patients body 4 Keep the patient from motion or hyperventilation 5 Check the connection between patient cable and electrodes Please use filter if still having above mentioned interference 10 5 Troubleshooting Trouble Possible Reason Solution Big interference Random waveform 1 It is firm whether the grounding connections 2 The joint of two sides of conductance line is not stable 3 A...

Страница 19: ...nd leader s plug part is not connection enough 5 the connection between patient cable and electrodes is not well 1 The alcohol of use is asked for well 2 Use ethyl alcohol to wash electrode wafer and the skin under the electrode 3 Be charged to the battery 4 The electrode reed tightly clip Baseline drift 1 The batteries are drained 2 Patient moves 1 Be charged to the battery 2 Keep patients quietl...

Страница 20: ...n key power supply acknowledgement shortcut menu Function Key Pause On Function Key System Menu Function Key Print Function Key Calibrate AC power is on no battery The battery solely powering and the battery is full of electricity The battery solely powering and the battery is not full of electricity The battery solely powering and the electric power is going to be used up On charging Danger volta...

Страница 21: ...rts due to production reasons Labor costs and personnel traveling expenses and packaging not included All components subject to wear are not included in the warranty The repair or replacement performed during the warranty period shall not extend the warranty The warranty is void in the following cases repairs performed by unauthorized personnel or with non original spare parts defects caused by ne...

Отзывы: