The Wind Page
can be used to select:-
North Alignment from
0
-359 degrees. If the unit is installed on the mast and found
to be off North alignment then an offset figure can be set to correct for this.
Sensor WindSpeed
ON
or OFF.
Wind Speed Units
MS,
KTS, MPH, KPH, FPM.
(Metres/Second, Knots (Nautical miles/hour), Miles/Hour, Kilometres/Hour, Feet/Minute).
No-Direction Wind Speed
0.00
m/s to 5.00m/s speed above which direction readings
are output.
The Temperature Page
can be used to select:-
Temperature Sensor
ON
or OFF
Temperature Units
C,
K or F (Centigrade, Kelvin, Fahrenheit)
Dew Point Sensor
ON
or OFF
Dew Point Units
C
, K or F
The Pressure Page
can be used to select:-
Pressure Sensor
ON
or OFF
Pressure Units
HPA
, MB, MMHG, INHG (Hecto Pascals, Milli-Bars,
Millimetres Mercury, Inches Mercury).