45
Model: GVH-C & GVH-F
Troubleshooting
Problem
Probable Cause
Corrective Action
Under-hood Appliance will not power-
up:
•
[HOOD POWERED]
light
ON
•
[CHARCOAL OR BAFFLE
FILTER
MISSING]
light
ON
•
[
APPLIANCE POWERED]
light
OFF
a. Baffle Filter missing or not
properly installed
Install Baffle Filter / check alignment.
b. Charcoal Filter missing or not
properly installed
Install Charcoal Filter / check
alignment.
c. One or both Filter switches are
faulty
Test & replace as needed.
Under-hood Appliance will not power-
up:
•
[HOOD POWERED]
light
ON
•
[CHARCOAL OR BAFFLE
FILTER
CLOGGED]
light
ON
•
[
APPLIANCE POWERED]
light
OFF
•
Continuous tone
alarm sounding.
a. Baffle or Charcoal Filter clogged Replace Charcoal Filter or clean Baffle
Filter.
b. Hood exhaust outlet excessively
block
Confirm exhaust is clear of any
obstruction around diverter.
c. Vacuum Switch (clogged filter
sensor) is out of adjustment
Test & adjust vacuum switch.
d. Kinked or blocked vacuum line Remove vacuum line kinks or
blockage.
e. Fan running slow or blades are
loaded with grease film
Check voltage and inspect blower,
clean if needed
Under-hood Appliance will not power-
up:
•
[HOOD POWERED]
light
ON
•
[
WASH]
light
ON
•
[
APPLIANCE POWERED]
light
OFF
•
Intermittent tone (beeping)
alarm
sounding.
a. Excessive film built up on
collector fins; too dirty
Clean the EAC cell,
Section 4.03.2
.
b. EAC cell is not installed
Install clean EAC cell.
c. EAC driver board is faulty
Test & replace EAC power supply if
needed.
d. Poor connection at contact
plate, dirty contacts, cell mis-
aligned, faulty contacts.
Check cell position, clean contacts,
inspect contact plate & replace if
needed.
Under-hood Appliance operates:
•
[HOOD POWERED]
light
ON
•
[CHECK
]
light
ON
•
[
APPLIANCE POWERED]
light
ON
•
No
alarm sounding, although cell is
NOT
cleaning air
.
a. Ionizer wire broken & touching
chassis.
Replace ionizer wire.
b. Collector fins shorted to ground
by moisture.
Dry cell, determine cause of
moisture, cool air being drawn into
hood creating condensation.
Under-hood lighting does not come on
when Power Switch is ON.
a. Fluorescent bulb burned out
Replace bulb.
b. Ballast is faulty
Replace ballast.
c. Fuse is blown
Check and replace fuse.
6.01 Procedures - continued
Содержание GVH-C
Страница 2: ......
Страница 4: ......
Страница 12: ...2 Model GVH C GVH F Introduction 1 04 Specifications 1 04 1 Overall Dimensions GVH C Counter Top Version ...
Страница 13: ...3 Model GVH C GVH F Introduction 1 04 1 Overall Dimensions GVH F Floor Stand Version ...
Страница 17: ...7 Model GVH C GVH F Installation 2 03 Clearance to Combustibles 2 03 1 GVH Counter Top Hood GVH C ...
Страница 18: ...8 Model GVH C GVH F Installation 2 03 2 GVH Floor Stand Hood GVH F ...
Страница 34: ...Model GVH C GVH F Overview 24 1 5 2 4 3 8 9 3 01 Control Panel 6 7 ...
Страница 36: ...26 Model GVH C GVH F Overview Optional Not Seen 3 02 Hood Front Filter Chamber 1 5 2 6 7 4 3 8 ...
Страница 49: ...39 Model GVH C GVH F Operation Filter Maintenance ...
Страница 56: ...46 Model GVH C GVH F Troubleshooting ...
Страница 60: ...50 Model GVH C GVH F Parts List Hidden Optional 7 03 Hood Front Filter Compartment 9 2 1 8 3 5 6 4 7 11 10 ...
Страница 64: ...54 Parts List Model GVH C GVH F 7 05 Under Hood Components 2 1 4 3 ...
Страница 66: ...56 Model GVH C GVH F Parts List ...
Страница 67: ......