Operation & Filter Maintenance
4.02.4.3
E.A.C. Filter Status & Alarm - continued
3. Inspect the cell for broken or missing ionizer wires, bent fins, or other damage. Ionizer wires are replaceable
(when ordering replacements, note that the
GVH
hood uses
20”
wires. Bent fins may be gently straightened by
hand, such that no fins are touching adjacent fins. A cell with excessive damage (broken/badly bent frame,
broken insulators, etc) must be replaced.
4. Inspect the E.A.C. contact pad inside hood. Clean grease accumulation away with a mild degreasing cleaner and
dry thoroughly.
5. Replace Filter Cell
(
Section 4.02.3
)
and restart hood
(Section 4.01.1)
. If the condition persist, contact a qualified
service technician. If none of the LED lights turn
ON
, the EAC power supply may be faulty.
4.03
Filter Maintenance
4.03.1
Baffle Filter Cleaning
4.03.2
E.A.C. Filter Cell Cleaning
Continued on Next Page
Grease baffle filter should be cleaned daily. Rotate the thumb-turn locks to the opening position and open filter.
Clean in sink with a mild, biodegradable, degreasing cleaner
(Giles recommends Simple Green®Crystal Foaming
Cleaner)
. Rinse and dry filter thoroughly. Close filter halves and secure the locking thumb-turns. Reinstall in the
unit. Generally, a baffle filter may be washed in a dishwasher.
Ensure that filter is completely dry before reinstalling in the hood. NEVER PLACE WET FILTER INTO HOOD!
The stainless steel baffle filter is fabricated from thin guage metal that can potentially have
sharp edges. Exercise due care when handling and cleaning to avoid injury.
It is
recommended that heavy-duty rubber gloves be worn
.
The E.A.C. collector cell contains parts fabricated from thin gauge sheet metal that can
potentially have sharp edges, which may cause cuts if not handled properly. To avoid injury,
exercise due care when handling and/or cleaning the cell.
It is recommended that heavy-
duty rubber gloves be worn as a precaution
.
The E.A.C. collector cell is sustainable and renewable; it should last for years if cleaned and handled properly. To
maintain peak performance, It
MUST BE CLEANED DAILY
. Not doing so can lead to an interruption of appliance
operation, premature failure of the electronic cleaning system, or reduced life for consumable charcoal filters.
Follow the procedures detailed below for effective cleaning.
IMPORTANT:
•
The cell CANNOT withstand washing in commercial dishwashing equipment.
•
Many commercial cleaners are not safe for use on aluminum ... use of the recommended cleaners is advised.
•
Dishwashing detergents are generally not suitable ... using can cause oxidation, or create a film on aluminum
collection fins that will lead to malfunction and result in interruption of power to under-hood appliances.
Содержание GVH-C
Страница 2: ......
Страница 4: ......
Страница 12: ...2 Model GVH C GVH F Introduction 1 04 Specifications 1 04 1 Overall Dimensions GVH C Counter Top Version ...
Страница 13: ...3 Model GVH C GVH F Introduction 1 04 1 Overall Dimensions GVH F Floor Stand Version ...
Страница 17: ...7 Model GVH C GVH F Installation 2 03 Clearance to Combustibles 2 03 1 GVH Counter Top Hood GVH C ...
Страница 18: ...8 Model GVH C GVH F Installation 2 03 2 GVH Floor Stand Hood GVH F ...
Страница 34: ...Model GVH C GVH F Overview 24 1 5 2 4 3 8 9 3 01 Control Panel 6 7 ...
Страница 36: ...26 Model GVH C GVH F Overview Optional Not Seen 3 02 Hood Front Filter Chamber 1 5 2 6 7 4 3 8 ...
Страница 49: ...39 Model GVH C GVH F Operation Filter Maintenance ...
Страница 56: ...46 Model GVH C GVH F Troubleshooting ...
Страница 60: ...50 Model GVH C GVH F Parts List Hidden Optional 7 03 Hood Front Filter Compartment 9 2 1 8 3 5 6 4 7 11 10 ...
Страница 64: ...54 Parts List Model GVH C GVH F 7 05 Under Hood Components 2 1 4 3 ...
Страница 66: ...56 Model GVH C GVH F Parts List ...
Страница 67: ......