Omnia PCB
Omnia Maintenance Through USB
Page 5-52
MDE-5369E FlexPay™ IV (with Omnia) Programming and Service Manual · April 2020
Omnia Maintenance Through USB
This section guides the service technician through this feature, from the USB flash drive setup
to the LED glowing sequence and its significance.
Introduction
Omnia USB Maintenance is a functionality that allows the ASC to perform the following
operations using a well-formatted USB flash drive:
• Software Update/Media Content Upload
• Log Retrieval
• Configuration retrieval
• Network Restore
Requirements
The following items are required for Setup Via USB Flash Drive:
• USB Flash Drive (hereafter referred to as “USB drive”) with at least 2GB free memory
• PC/Laptop
• Text Editor tool (e.g. +)
USB Drive Preparation
Plug USB drive into your PC/Laptop and create a folder tree as shown in the following figure:
Figure 5-76: Folder Structure