Omnia Setup with Wizard - New Configuration
Omnia PCB
MDE-5369E FlexPay™ IV (with Omnia) Programming and Service Manual · April 2020 Page 5-9
6
Use the following table for Omnia configuration settings:
Field
Configuration Settings
Dispenser Model
Encore or Latitude
Site dispenser type
Dual-sided or Single-sided Unit
Select Two-wire
Connection Type
MOC or Generic. Ensure that the UPM and Omnia are set to the same connection
type.
When this parameter is changed (from MOC to Generic or Generic to MOC), a reboot
is required. Reboot the Omnia board from the Tools tab or warmstart the dispenser.
Wait for 10 seconds before reapplying power.
Select Pump Baud Rate
No change. Setting should remain at Default (5787).
Dispenser Serial Number
Enter the serial number given on the dispenser side label.
SIDE A fueling position
Fueling position number of Side A. Side A is the side where the Calibration Switch is
located.
SIDE B fueling position
Fueling position number of Side B
Serial Pump Connection
Type
Select from the following options:
• With Remote Management of Door Sensors: PCN version 04.xx or later and set
to RTP-serial.
• Without Remote Management of Door Sensors: Set to ZModem. This is the
default value.
• If the pump connected is an E300: Set to None. This type of pump has no
ZModem cable.
To manage door sensors remotely through the Cloud, program the pump to use Real
time Protocol. For more information, refer to MDE-3860 Programming Quick
Reference Guide.
Side A External IP Address
For Side A External IP address configuration, refer to “IP Scheme FlexPay IV” on
for Gilbarco default settings. This field is auto-populated with 10.5.55.XX
(XX depends on Side A fueling position entered, 70 + ID). Will need to be changed if
site using custom External IP Addresses.
Note: These IP addresses may be different based on the site’s IP scheme.
Side B External IP Address For Side B External IP address configuration, refer to “IP Scheme FlexPay IV” on
for Gilbarco default settings. This field is auto-populated with 10.5.55.XX
(XX depends on Side A fueling position entered, 70 + ID). Will need to be changed if
site using custom External IP Addresses.
Note: These IP addresses may be different based on the site’s IP scheme.
Side A-B External Netmask External subnet mask (default 255.255.255.0)
Backroom Router IP
Address (Gateway)
Backroom Router IP address
(Generic CRIND) Pump
2-Wire ID Side A (1-16)
Note: For MOC, the pump ID for side A will be hard-coded 7.
(Generic CRIND) Pump
2-Wire ID Side B (1-16)
Note: For MOC, the pump ID for side B will be hard-coded 11.
Primary DNS
Enter the customer-provided DNS IP address or enter 10.5.55.1 as default. Note that
this field may also use non-default values. Consult the site’s IT Department for IP
Settings in the back room.
Note: These IP addresses may be different based on the site’s IP scheme.
Secondary DNS
Google Public IP 8.8.8.8. Be aware that this field may also use non-default values.
Consult the site’s IT Department for IP Settings in the back room.
Note: These IP addresses may be different based on the site’s IP scheme.
Current Login Mode
Indicates if No Authentication, Access Code (set by customer), or Rolling Password
(ASC Tool).