![GILBARCO VEEDER-ROOT FlexPay IV Insite360 Encore Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/gilbarco-veeder-root/flexpay-iv-insite360-encore/flexpay-iv-insite360-encore_programming-and-service-manual_2227135027.webp)
Pre-requisites for Installing Omnia in FlexPay IV
Configuring FlexPay IV
MDE-5369E FlexPay™ IV (with Omnia) Programming and Service Manual · April 2020 Page 4-5
7 In the VFI Device Config, press <
1
> for VFI device IP
assignment.
8 Follow the wizard procedure and push the Device Back
button.
The message “Device message received. Please wait...” is
displayed on the screen.
After the procedure is complete, the system will report the
new IP address of the VFI device (default value from factory
is 172.16.100.2); then, proceed with the following:
9 Press
OK.
10 Reboot the system.
Note:
The card reader will return to the default address.
Both Side A and Side B card readers will have the
same IP address of 172.16.100.2; therefore, any
replacement of a card reader during a future
service will come out of the box set properly (no
need to set IP). Omnia VLAN combined with the
location of CAT5 cables on Omnia associates the
card reader to the UPM for each side (card reader
A with UPM A; card reader B with UPM B).
Description
Screen