FlexPay II DCM2.1
Unit
Default IP Address
Side A
172.16.100.1
Side B
172.16.100.3
Netmask
255.255.255.0
Default Gateway
172.16.100.254
SM Server
10.5.55.66
FlexPay IV DCM2.1
Unit
Default IP Address
UPM A
172.16.100.1
UX 300 A
172.16.100.2
UPM B
172.16.100.3
UX 300 B
172.16.100.4
GSoM A
172.16.100.5
GSoM B
172.16.100.6
Default Gateway
172.16.100.254
Netmask
255.255.255.0
SM Server
10.5.55.66
MDE-4902E Encore® 700 S Start-up and Service Manual · February 2018
Page 3-7
Configuring Network with DCM2.1 (with SSoM) and Later Hardware
Start-up
The IP addressing scheme for the units with SSoM is 172.16.100.XXX.
Note: Each dispenser with an SSoM can be set to the same IP scheme across the entire
forecourt. The SSoM will need to be configured. For more information, refer to
MDE-5314 Insite360 Encore Remote Management Installation, Start-up, and Service
Manual.