MDE-4902E Encore® 700 S Start-up and Service Manual · February 2018
Page 3-3
CRIND Mode
Start-up
2
Press
1
>
Enter
. The CRIND ID Side 1 screen is displayed. (see
Note: Each CRIND device is programmed separately by inserting the CRIND diagnostic card
on each side (cannot be done from the same side). The CRIND ID screen is called
“Side 1” irrespective of the side being programmed.
Figure 3-4: CRIND ID Side 1
CRIND ID Side 1
CRIND ID 1
(Range: 1 - 32, 99 = disable)
Number Keys = Direct Entry
Clear = Erase Entry
Enter = Save Value and Exit
Cancel = Discard Change and Exit
The current CRIND communication
address for side 1.
3
Press numeric keys to enter one-digit or two-digit CRIND ID. To enter a two-digit CRIND ID,
for example, 32, press
3
>
Enter
and
2
>
Enter
. Legal values for this field are 1-32 and 99.
Setting the value as 99 configures the side not to answer polls on the CRIND communication
loop. This is useful for field troubleshooting and diagnostic purposes.
4
Press
Enter
to save the edited CRIND ID and exit. The CRIND IDs menu is displayed.
~ OR ~
Press
Cancel
to discard changes and exit. The program returns to the CRIND IDs menu.
CRIND Mode
To configure the CRIND Mode, proceed as follows:
1
From the CRIND Config menu, press
2
>
Enter
. The CRIND Mode menu is displayed.
Figure 3-5: CRIND Mode
CRIND Mode
CRIND Mode MOC
1. MOC
2. Generic
Enter = Save Value and Exit
Cancel = Discard Change and Exit
Shows current setting. For new
installations or CRIND devices that have
undergone a purge or BIOS coldstart,
default will not be configured.