Start-up
Configuring Network for Sites with DCM2 or Earlier (without SSoM)
Page 3-4 MDE-4902E Encore® 700 S Start-up and Service Manual · February 2018
2
Press the following numeric keys followed by
Enter
to change the current CRIND Mode
setting:
•
1
causes the unit to operate in Major Oil Company (MOC) CRIND Mode.
•
2
causes the unit to operate in Generic CRIND Mode.
3
Press
Enter
to save changes and exit. The CRIND Config menu is displayed.
~ OR ~
Press
Cancel
to discard changes and exit. The program returns to the CRIND Config menu.
Configuring Network for Sites with DCM2 or Earlier
(without SSoM)
CRIND side Internet Protocol (IP) addresses must not be changed from factory default
unless one of the following three conditions apply:
1) The site requires a non-standard IP scheme.
2) The site is configured for non-standard CRIND IDs.
3) Some third-party Point of Sale (POS) systems start with “0” instead of “1” as their
first CRIND ID.
For example, dispenser 1 is configured for CRIND IDs 1/4 instead of 1/2.
WARNING
WARNING
!
Note: The CRIND device on each side is independent of the CRIND device on the other side.
Each side must be programmed individually.
From the Main Menu, press
3
>
Enter
. The Network Config menu is displayed.
Figure 3-6: Network Config Menu
Network Config
1. Reset to Default IPs
2. Set IP Addresses
3. Apply Network Settings
4. View Network Settings
5. Hide Network Settings
Cancel = Exit