Service
Encore 700 S PCBs
Page 4-8 MDE-4902E Encore® 700 S Start-up and Service Manual · February 2018
Service LED
The following table lists the service LED status details:
Status
Description
Flashing
No communication
Off
Normal operation
Status/Error LED
The following table lists the status/error LED status details:
Status
Description
Green blinking
Normal communication
Red
Error
shows the Encore 700 S Peripheral Interface PCB (PIP).
Figure 4-7: Encore 700 S PIP (M09112A001) Printed Circuit Assembly (PCA)
To TRIND
Connect to Pump Download
Port (A Side only)
To Cash Acceptor
through P302x on HIP
To Barcode
Interface Board
3-pin Power Input
Beeper Volume:
Low = None
Medium = Jumper Left
Loud = Jumper Right
Beeper Input from UPT CRIND
USB Connection to UPT CRIND