MDE-4902E Encore® 700 S Start-up and Service Manual · February 2018
Page 3-9
Configuring Network with DCM2.1 (with SSoM) and Later Hardware
Start-up
Setting IP Addresses
From the Network Config menu, press
2
>
Enter
. The Set IP Addresses menu is displayed.
Both Side A IP address and Side B IP address must be programmed on each side of
the dispenser. Side A is the side that you are in front of each time.
IMPORTANT INFORMATION
Figure 3-9: Set IP Addresses
Set IP Addresses
1. Set CRIND Side A IP
2. Set CRIND Side B IP
4. Set SMART Merchandising Server IP
5. Set Netmask Address
6. Set Gateway Address
Cancel = Exit
Setting CRIND Side A IP
From the Set IP Addresses menu, press
1
>
Enter
. The CRIND Side A IP screen is displayed.
Figure 3-10: CRIND Side A IP (example without SSoM)
CRIND Side A IP
000 . 000 . 000 . 000
Enter number blocks using three digits each with
leading zeros if necessary.
IP block range: 000 – 255
Example: 010 . 005 . 055 . 071
Clear = Erase Entry
Enter = Save Value and Exit
Cancel = Discard Changes and Exit
Notes: 1) When setting the IP Addresses, press Enter after each digit. For example, for IP
address 10.5.55.77, press 1 > Enter, 0 > Enter, . > Enter, and so on.
2) Default IP addresses will always be 10.5.55.70 + the set CRIND ID.
To set Side A IP address, number block must be in the 000-255 range and has to be completed
with leading zeros as follows:
• Press
Clear
to erase all entered digits and start again.
• Press
Enter
to validate if it is a correct IP address and to store the result. If the IP address
is not valid the input is cleared.