Series 8650A Universal Power Meters
2-34
Manual 31470, Rev. E, April 2001
Like the Peak Hold feature, the Crest Factor feature also has the same minimum average power level
restriction of -20 dBm. Beginning in firmware version 1.51, this has been implemented to increase
accuracy and maintain wide bandwidth of Crest Factor measurement over the peak power range of
-20 dBm to +20 dBm. The Crest Factor selection will also affect Histogram measurement if there is
power below -20 dBm. To obtain accurate average power measurements below -20 dBm, remove the
display line containing Crest Factor (or, in remote control, by sending the command which disables the
Crest Factor feature).
NOTE:
[Reset Line n] for the Crest Factor also resets Peak Hold.
☛
☛
☛
☛