Remote Operation
Manual 31470, Rev. E, April 2001
3-115
Table 3-18: Error Code Returned in Position aa
Error
Code
Message
Notes
00
All OK.
50
Entered Cal Factor out of range.
Enter value between 1.0% and 150.0%
51
Entered Offset out of range.
Enter value between
-99.999 dB and +99.999 dB
53
Entered average number out of range.
Enter valid average number.
54
Entered recall memory number out of range.
Enter valid recall memory number between 0
and 20.
55
Entered store memory number out of range.
Enter valid store memory number between 1
and 20.
60
Unable to set requested measurement mode or
sensor measurement because sensor A is
unattached or uncalibrated.
This may be due to receipt of a MAP, PAP,
BAP, DC1, or DY command.
61
Same as Error 60 above, but for sensor B.
62
Unable to set up sensor A to perform a modulated
measurement (MAP, PAP, or BAP), because the
sensor is not a modulated sensor. OR: Unable to
modify a BAP measurement because the sensor is
not a modulated sensor.
This may be set due to receipt of a MAP, BAP,
DC1, DY, BSTE, BSPE, or BTDP command.
63
Same as Error 62, but for sensor B.
67
Unable to activate Peak Hold or Crest Factor
features.
This may be set due to receipt of a CR1 or
PH1 command. Peak Hold and Crest Factor
can be enabled only in MAP, PAP, or BAP
modes.
68
Unable to initiate fast measurement collection mode.
Verify using modulation sensor and
measurement mode selections.
70
Entered peak sensor A data error.
Check entered data.
71
Entered peak sensor B data error.
Check entered data.
72
Entered peak sensor A delay out of range.
Check entered delay.
73
Entered peak sensor B delay out of range.
Check entered delay.
74
Entered peak sensor A trigger out of range.
Check entered trigger value.
75
Entered peak sensor B trigger out of range.
Check entered trigger value.
76
Sensor EEPROM data entry has error.
Check entry data.
77
Sensor A does not exist.
Check sensor A. This error code refers only to
the EEPROM command.
78
Sensor B does not exist.
Check sensor B. This error code refers only to
the EEPROM command.
79
Measurement settling target for auto-average mode
is out of range.
Value must be 0.10% to 100.00%.
81
Duty cycle out of range.
Value must be between 0.001% and
99.999%.
82
Frequency value out of range.
Value must be between 0 Hz and 100 GHz.
85
Resolution value out of range.
Value must be between 0 and 3.
90
GPIB data parameter error.
Check, then enter with valid prefix.
91
Invalid GPIB code.
Check, then enter with correct code.
Содержание 8650A Series
Страница 4: ......
Страница 12: ...Series 8650A Universal Power Meters viii Manual 31470 Rev E April 2001 ...
Страница 16: ...Series 8650A Universal Power Meters xii Manual 31470 Rev E April 2001 ...
Страница 18: ...Series 8650A Universal Power Meters xiv Manual 31470 Rev E April 2001 ...
Страница 20: ...Series 8650A Universal Power Meters xvi Manual 31470 Rev E April 2001 ...
Страница 32: ...Series 8650A Universal Power Meters 1 12 Manual 31470 Rev E April 2001 ...
Страница 198: ...Series 8650A Universal Power Meters 3 124 Manual 31470 Rev E April 2001 ...
Страница 216: ...Series 8650A Universal Power Meters A 8 Manual 31470 Rev E April 2001 ...
Страница 228: ...Series 8650A Universal Power Meters B 12 Manual 31470 Rev E April 2001 ...
Страница 240: ...Series 8650A Universal Power Meters Index 6 Manual 31470 Rev E April 2001 ...