48
UK
UK
49
UK
BA24
BA24
0 0 0
5
ESC
-
OK
0 0 0 5
ESC
-
OK
+
0
0
0 5
ESC
-
OK
+
0 0
0
5
ESC
-
OK
+
+
H 1
ESC
-
OK
+
The digits on the lcd are still fixed to shown that is not possibile any
modification.
The b and – are irrelevant
The ESC button return to the upper level
With OK button you enter the selected menu and the digits begin
blinking.
A digit of the lcd blinks (depending on the menu the blinking digit could
be different).
With + and – buttons you can modify the value of the blinking digit.
The ESC button moves the blinking digit to the left until the first digit
you can modify.
With OK you confirm and go to the next step.
The next digit starts blinking
With + and – buttons you can modify the value of the blinking digit.
The ESC button moves the blinking digit to the left until the first digit
you can modify.
With OK you confirm and go to the next step
The next digit starts blinking
With + and – buttons you can modify the value of the blinking digit.
With OK you confirm and go to the next step
The ESC button moves the blinking digit to the left until the first digit
you can modify.
By means of + or – buttons you can select the submenus (H1, H2, H3,…)
The digits on the lcd are fixed to show that is no possible any
modification.
The button ESC lets you to go to the upper level (menus A, C, F, H E).
With OK button you enter the selected menu and the value set is shown.
H 1
ESC
-
OK
+
Appears again menu H1.
With ESC return to the upper level (menu A, C, F, H, E)
Menu
Function
Description
Leaf 1 opening time.
Tmax 300 s.
Leaf 1 closing time.
Tmax 300 s
Leaf 1 operating time in deceleration mode.
Tmax 100 s
Leaf 2 opening time.
Tmax 300 s
Leaf 2 closing time.
Tmax 300 s
Leaf 2 operating time in deceleration mode.
Tmax 100 s
Delay the START in opening of leaf 2 with respect to leaf 1.
In the case of a configuration with double sliding gate, the time H7
will not be considered.
Tmax 100 s
Delay the START in closing of leaf 1 with respect to leaf 2.
In the case of a configuration with double sliding gate, the time H8
will not be considered.
Tmax 100 s
Determines the pause time in opening before automatic closing.
Tmax 300 s
Determines the pedestrian opening time
Determines the pause time in pedestrian opening before automatic
closing.
Tmax 300 s
MOTOR 1 OPENING TIME
MOTOR 1 CLOSING TIME
MOTOR 1 DECELERATION TIME
MOTOR 2 OPENING TIME
MOTOR 2 CLOSING TIME
MOTOR 2 DECELERATION TIME
LEAF 2 PHASE SHIFT TIME
IN OPENING
LEAF 1 PHASE SHIFT TIME
IN CLOSING
AUTOMATIC CLOSING PAUSE TIME
PARTIAL OPENING TIME
AUTOMATIC PEDESTRIAN
CLOSING PAUSE TIME
H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
H11
A C F
H
E
ESC
-
OK
+
When the display shows the main menus (letters A C F H E or just
some of them depending on which password has been used to access
programming) let the letter H blink by moving to the right or to the left
with the b or –
Once the letter H blinks confirm with the OK button.
MENU H: TIME SETTINGS
Example Programming
MENU H
Description
MENU H
All the times can be set in steps of 1 s