36
UK
37
UK
BA24
BA24
30
31
JP5
GND
ANT
ANTENNA BRAID input
ANTENNA SIGNAL input
JP6
Connector for plug-in radio receiver
18
19
29
27
20
21
22
23
24
25
26
28
JP3
START
PED
STOP
FCAM1
FCCM1
FCAM2
FCCM2
RESERVE
PH2
PH1
EDGE
COM
START input (N.O.)
PEDESTRIAN input (N.O.)
COMMON INPUTS-OUTPUTS
STOP input (N.C.).
If not used, jumper with terminal n° 29
Opening limit switch input - motor 1 (N.C.)
If not used, disable during programming
Closing limit switch input - motor 1 (N.C.)
If not used, disable during programming
Opening limit switch input - motor 2 (N.C.)
If not used, disable during programming
Closing limit switch input - motor 2 (N.C.)
If not used, disable during programming
Multifunctional input
PHOTOCELL 2 input (N.C.).
If not used, disable during programming or jumper with terminal n. 29
Operation
:
Input active during both opening and closing.
If intercepted, it immediately stops the motion and holds it stopped until the photocell
is freed. Upon release, motion always restarts in opening.
If intercepted when the gate is closed, following a START command, it does not allow
opening the gate and it will be signalled with 5 fast flashes, then the warning light
turns on to indicate that the gate is in stand-by. Upon release, the gate will START
opening without further commands.
If intercepted during pause, it reloads the pause time.
PHOTOCELL 1 input (N.C.).
If not used, disable during programming or jumper with terminal n. 29
Operation
:
Input active only during closing.
It stops and inverts the motion, opening the gate completely.
If the gate is closed, it does not affect its functioning.
If intercepted during pause, it reloads the pause time.
SAFETY DEVICES input (see menu C9)
If not used, disable during programming.
Operation
:
Input active during both opening and closing.
It stops and inverts the motion for 2 sec. The gate will remain locked until the next
START pulse, which will restart it in the obstacle freeing direction.
When active in stand-by, after the START/pedestrian the door does not move and
3 long flashes (2 sec.) will signal the anomaly.
If active in pause, the door does not close automatically (if expected) and 3 long
flashes (2 sec.) will signal the anomaly.
External clock:
See
PROGRAMMING E9
SIGNALLING LED
Description
Position
Colour
Signal
Lights when the START command is activated and turns off immediately after
Lights when the PEDESTRIAN command is activated and turns off immediately after
Always on. It turns off when the STOP command is activated
Always on.
It turns off when reaching the motor 1 OPENING LIMIT SWITCH
Always on.
It turns off when reaching the motor 1 CLOSING LIMIT SWITCH
Always on.
It turns off when reaching the motor 2 OPENING LIMIT SWITCH
Always on.
It turns off when reaching the motor 2 CLOSING LIMIT SWITCH
Lights when the contact switch from open to close and remain on until the contact
switch off
Always on. It turns off when the photocell 2 is intercepted
Always on. It turns off when the photocell 1 is intercepted
Always on. It shows logic circuit power supply
DL1
DL2
DL3
DL4
DL5
DL6
DL7
DL11
DL8
DL9
DL12
GREEN
GREEN
RED
RED
RED
RED
RED
RED
RED
RED
GREEN
START
PEDESTRIAN
STOP
FCAM1
FCCM1
FCAM2
FCCM2
RESERVE
PHOTO2
PHOTO1
VCC
Description
Position
Value
Type
Accessories and motor protection, power supply from battery charger circuit
Equipment, motor and safety devices protection
Accessories protection
F1
F2
F3
15 A
15 A
500 mA
/
/
FAST
PROTECTION FUSES