52
UK
UK
53
UK
BA24
BA24
E5
E7
E9
INVERSION FROM
PEDESTRIAN
COURTESY LIGHT
WITH TWO MOTORS
EXTERNAL CLOCK
1
1
1
2
3
3
2
During the PEDESTRIAN closing, the PHOTO 1 – PHOTO 2 –
PEDESTRIAN – START command causes the complete opening.
Courtesy light not activated with 2 motors
Disables the RESERVE input (CLOCK NOT ACTIVE)
EXTERNAL CLOCK - CLOSING ALLOWED
Enables the RESERVE input for the connection of an external clock.
Operation:
With the closed contact on the RESERVE input, following a START
command, the door will open but it will not close automatically.
Following the contact closing, the door will close automatically after
the pause time.
When the door is open, the closing command can be given with
“START” if the menu is STEP-BY-STEP or STEB-BY-STEP WITH
STOP.
WARNING
: remember to preset the automatic closing
EXTERNAL CLOCK - CLOSING NOT ALLOWED
Enables the RESERVE input for the connection of an external clock.
Operation:
With the closed contact on the RESERVE input, following a START
command, the door will open but it will not close automatically.
Following the contact closing, the door will close automatically after
the pause time.
It is not possible to activate the closing with the START command.
WARNING
: remember to preset the automatic closing
Courtesy light activated with 2 motors
Operation:
Active on the electrical lock output 2 for 3 minutes after the end of the
motors movement
During the pedestrian closing, the PHOTO 1 – PHOTO 2 –
PEDESTRIAN command opens only the pedestrian.
The START command causes the complete opening.
E9
E90
E92
E94
E96
E98
EXTERNAL CLOCK
CYCLES NUMBER
INSTALLER CODE
FIRMWARE RELEASE
NUMBER OF PERFORMED
CYCLES
NUMBER OF POWER
SUPPLY DAYS
4
EXTERNAL CLOCK - AUTOMATIC OPENING AND CLOSING
COMMAND
Enables the RESERVE input for the connection of an external clock
Operation:
With the closed contact on the RESERVE input, an automatic opening
command will activate (with no need of a START command).
The door will open, but it will not close automatically. Following the
contact closing, the door will close automatically after the pause time.
It is not possible to activate the closing with the START command.
WARNING:
remember to preset the automatic closing
Allows the setting of a number of cycles (o closing) before
the maintenance request.
The value set will always be multiplied for 10.
If 0000 is set, the numbering is excluded.
When the set number of cycles is reached, the maintenance request
is signalled by a slow blink of 60 sec. at the end of the movement.
The signalling will be blinking even if the C2 menu is set up with fixed
light.
WARNING:
Each time you enter in E90 menu (WITH BLINKING NUMBERS,
THAT MEANS READY TO BE MODIFIED) the count of the cycles
number resets starting from the beginning.
Allows the input of the installer code to customize the settings during
the programming phase.
The INSTALLER CODE is the only way to enter the programming
menu.
Shows the firmware release installed on the equipment.
(XX__YY)
Number of performed cycles. The value displayed on the LCD screen
is increased every 10 movements
Number of control unit power supply days.
The data increments when the 24 hours expire.
Possible lacks of power supply reset the count of last day.
E3
SAFETY DEVICES TEST
1
2
Disables the safety devices test
Enables the safety devices test.
Operation:
PHASE 1
: when the START or the Pedestrian command is given, the
amperometric circuit is tested. If an anomaly is detected, it will be
indicated by 4 slow blinks (2 sec.) of the flashing light.
PHASE 2
: If the edge with N.C. contact is enabled (menu C9-3),
when the START or PEDESTRIAN command is given, the power to
the safety devices is cut off for 0,5 seconds and then restored: if the
inputs of the safety devices open and immediately go back to N.C.,
the motors START, otherwise a fault is signalled with 3 long flashes
(2 sec.).
PHASE 3
: if the edge 8K2 is enabled (menu C9-2), when the START
or the PEDESTRIAN command is given, the SAFETY DEV. Input is
tested (value 8K2). If the value is not correct, the fault is signalled with
2 long flashes (2 sec.).
WARNING
: The indication of the fault detected will be only one (the
first one to be detected) even if there is more than one fault.
Содержание BA24
Страница 59: ...59 NOTE NOTES BA24 ...