INSTALLATION INSTRUCTIONS

Installation Checklist
Location
  •  Is the water heater located within the venting requirements and close to the main use of hot water? ....  

L

  •  Is the water heater protected from freezing temperatures? ......................................................................  

L

  •  Has a drain pan been installed and piped to a free-flowing drain?  .........................................................  

L

  •  Is the gas control valve accessible for servicing? .....................................................................................  

L

  •  Have clearances from combustible materials been observed? ................................................................  

L

Combustion and Ventilation Air Supply
  •  Is the area around the water heater clean and properly ventilated? ........................................................  

L

  •  Is the fresh air supply free of corrosive elements and flammable vapours? ............................................  

L

  •  Does the water heater have access to enough fresh combustion air? .....................................................  

L

  •  Have the fresh air openings been sized correctly and  

   has consideration been given to the blocking effect of louvers and grilles? ............................................  

L

Venting
  •  Is the flue baffle installed in the flue tube? ...............................................................................................  

L

  •  Has the water heater been vented separately from all other appliances? ...............................................  

L

  •  Have only PVC or CPVC pipe and fittings approved to ULC S636 standard

     been used to assemble the vent piping? ..................................................................................................  

L

  •  Have all horizontal runs of vent pipe been installed with a minimum rise of

    

1

/

4

 inch per foot (21 mm/m) of run? ...........................................................................................................  

L

  •  Has all the vent piping been secured with the appropriate primer and solvent-based cement? ..............  

L

  •  Has the venting been supported at the proper intervals? .........................................................................  

L

  •  Have precautions been taken against condensation flowing into the power venter? ...............................  

L

Water Piping

  •  Is the dip-tube installed in the cold water inlet? ........................................................................................  

L

  •  Has a temperature and pressure-relief valve been installed? ..................................................................  

L

  •  Does this valve have a discharge line installed, and is it piped to a free-flowing drain? .........................  

L

  •  Have all the plumbing connections been properly installed, and are they leak free? ..............................  

L

  •  Is the water heater full of water? ...............................................................................................................  

L

Gas Connections

  •  Is the gas supplied to the water heater the same type as indicated on the water heater rating plate? ...  

L

  •  Has the gas line been installed with a manual shut-off valve, union, and drip leg? .................................  

L

  •  Is the gas piping large enough and made of an approved material? .......................................................  

L

  •  Have all connections been made with an approved joint compound? .....................................................  

L

  •  Has the gas piping been tested for leaks with a soap and water solution? .............................................  

L

Wiring

  •  Has the wiring been properly installed? ....................................................................................................  

L

  •  Have the electrical connections been checked, and are they secure? ....................................................  

L

  •  Is the water heater electrically grounded? ................................................................................................  

L

  •  Does the 120V wall receptacle have the proper polarity? ........................................................................  

L

Содержание LIGHT DUTY COMMERCIAL POWER VENT GAS-FIRED WATER HEATERS

Страница 1: ...ersonal injury or death DO NOT store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance...

Страница 2: ...ur Water Heater 18 Replacement Parts 19 Troubleshooting Guide 20 Warranty 23 SAFETY INFORMATION Your safety and the safety of others is extremely important during the installation operation and servic...

Страница 3: ...m the top see Figure 1 3 INSTALLATION INSTRUCTIONS IMPORTANT These instructions have been written as a guide for the proper installation and operation of your water heater and the manufacturer of this...

Страница 4: ...BTU 4 8 m3 kW of the total input rating for all gas appliances installed in that space Water heaters installed in confined spaces require additional air This can be provided in two ways In Canada ref...

Страница 5: ...tecting the openings Screens must not be smaller 5 INSTALLATION INSTRUCTIONS Install above insulation Vent to outdoors Outlet air to attic 1 in2 4 000 BTU h Confined space Inlet air duct 1 in2 4 000 B...

Страница 6: ...stall the venting system could result in property damage personal injury or death Before installing the vent piping make sure that the vent system layout has been properly planned Verify that the loca...

Страница 7: ...2 inches 30 cm Shall not install Clearance to permanently closed window Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of two 2 feet 61 cm from the cen...

Страница 8: ...t all horizontal runs have a minimum rise of 1 4 inch per foot 21 mm m of run see Figure 10 When the installation is completed the vent terminal must be a minimum of eighteen 18 inches 45 7 cm from th...

Страница 9: ...installed into the relief valve The discharge line Must not be smaller than the outlet pipe size of the relief valve Must not terminate less than six 6 inches 15 2 cm and not more than twelve 12 inche...

Страница 10: ...t size of piping for this water heater consult CAN CSA B149 1 National Gas and Propane Installation Codes in Canada and or the National Fuel Gas Code ANSI Z223 1 NFPA 54 in the United States Only new...

Страница 11: ...tanks 4 Do not use toxic chemicals to clean the potable water heating system 5 Where water temperature in excess of 140o F 60o C is required for a space heating application a mixing valve must be inst...

Страница 12: ...uses an external electrical source for power It must be electrically grounded in accor dance with all local codes or in the absence of local codes CSA C22 1 Canadian Electrical Code in Canada and or t...

Страница 13: ...n installed with a minimum rise of 1 4 inch per foot 21 mm m of run L Has all the vent piping been secured with the appropriate primer and solvent based cement L Has the venting been supported at the...

Страница 14: ...our water heater immedi ately contact a qualified installer service agency or the gas supplier DO NOT light this water heater if It is not full of water The gas supplied does not match the type listed...

Страница 15: ...ature See Figure 13 for an explanation of what each of the temperature indica tors mean To decrease the temperature press and release the COOLER button once The temperature indi cators will now displa...

Страница 16: ...y occur 1 When the water heater is filled with cold water for the first time 2 If the water heater has been undersized 3 When large amounts of hot water are drawn from the water heater in a short peri...

Страница 17: ...t may be required Under no circumstances is the anode to be removed from the water heater on a permanent basis Removal of the anode will lead to premature failure of the water heater and void the warr...

Страница 18: ...listed in the Troubleshooting Guide does not solve the problem or if your par ticular problem is not listed in the guide contact the installer of the water heater or the local gas utility 3 If you sti...

Страница 19: ...bly 4 Complete burner assembly 5 Outer access door 6 Inner access door 7 Drain valve 8 Overflow tube 9 Dip tube 10 Temperature pressure relief valve 11 Flue baffle 12 Complete blower assembly 13 Vent...

Страница 20: ...that the hot surface ignitor and flame sensor rod are wired correctly and in good working condition 5 Low voltage to the water heater Check and repair 7 The gas valve driver circuit 1 Turn off the po...

Страница 21: ...w gas control valve High operating costs Gas control valve set too high Turn temperature dial to desired temperature Sediment or lime in tank Drain Check to see if water treatment is necessary Water h...

Страница 22: ...m up Problem should go away If it persists check all plumbing connections for leaks Heavy draws of hot water with very cold refill water Let water heater warm up Problem should go away If it persists...

Страница 23: ...10 If the heater is operated at water temperatures exceeding the maximum setting of the operating or high limit control or the heater is not supplied with potable water free to circulate at all times...